Key result
Application of the Cl- channel blocker DIDS or lowering external Cl- concentration blocked approximately 85% of the initial outward current during Ca2+ alternans in rabbit ventricular myocytes.
Why the study?
Does Ca2+-activated Cl- current play a role in shaping beat-to-beat alternations in AP morphology during cardiac alternans in rabbit ventricular myocytes?
Does Ca2+-activated Cl- current play a role in shaping beat-to-beat alternations in AP morphology during cardiac alternans in rabbit ventricular myocytes?
Ca2+-activated Cl- current (ICaCC) plays a critical role in shaping beat-to-beat alternations in action potential morphology during cardiac alternans, a high-risk indicator for arrhythmias.
May implicate ICaCC in rabbit alternans currents; leaves open human relevance and therapeutic translation.
Cardiac alternans, defined beat-to-beat alternations in contraction, action potential (AP) morphology or cytosolic Ca transient (CaT) amplitude, is a high risk indicator for cardiac arrhythmias. We investigated mechanisms of cardiac alternans in single rabbit ventricular myocytes. CaTs were monitored simultaneously with membrane currents or APs recorded with the patch clamp technique. A strong correlation between beat-to-beat alternations of AP morphology and CaT alternans was observed. During CaT alternans application of voltage clamp protocols in form of pre-recorded APs revealed a prominent Ca(2+)-dependent membrane current consisting of a large outward component coinciding with AP phases 1 and 2, followed by an inward current during AP repolarization. Approximately 85% of the initial outward current was blocked by Cl(-) channel blocker DIDS or lowering external Cl(-) concentration identifying it as a Ca(2+)-activated Cl(-) current (ICaCC). The data suggest that ICaCC plays a critical role in shaping beat-to-beat alternations in AP morphology during alternans.
No takes yet. Share an insight, caveat, or question.
Kanaporis et al. (2016) studied Cardiac alternans. Cl(-) channel blocker DIDS or lowering external Cl(-) concentration was evaluated on Blockade of initial outward current. Application of the Cl- channel blocker DIDS or lowering external Cl- concentration blocked approximately 85% of the initial outward current during Ca2+ alternans in rabbit ventricular myocytes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: