Why the study?
Does plasma measurement of D-dimer using the ELISA technique accurately diagnose suspected venous thromboembolism?
Population
2,245 patients clinically suspected of venous thromboembolism, comprising 1,337 patients suspected of deep…
Comparison
Plasma measurement of D-dimer using the ELISA… vs Latex assays.
Design
Meta-analysis
Authors
Loading...
Supports ruling out suspected VTE with negative ELISA D-dimer; confirms high sensitivity in aggregated diagnostic studies.
Does plasma measurement of D-dimer using the ELISA technique accurately diagnose suspected venous thromboembolism?
A low concentration of plasma D-dimer measured by ELISA (typically <500 micrograms/l) is highly sensitive and can be effectively used to rule out venous thromboembolism in clinically suspected patients.
Bounameaux et al. (1994) studied this question.