Key result
Latex-enhanced immunoturbidimetry enables reliable D-dimer measurement in serum instead of plasma.
Why the study?
Serum is traditionally considered unsuitable for D-dimer assays due to potential fibrinolytic activity causing falsely increased concentrations, necessitating evaluation of alternative measurement methods.
Can latex-enhanced immunoturbidimetry be used to accurately determine D-dimer concentrations in serum samples?
Can latex-enhanced immunoturbidimetry be used to accurately determine D-dimer concentrations in serum samples?
Latex-enhanced immunoturbidimetry enables the use of serum for D-dimer testing, challenging the traditional belief that only plasma is suitable.
Answers are grounded in this paper and cite their sources.
D-dimer reliably signals coagulation activation; leaves open expanded diagnostic roles pending validation studies.
Quantitative D-dimer determination has become routine practice in patients evaluated for the presence of deep venous thrombosis or pulmonary emboli (1)(2)(3). D-Dimer concentrations below a certain cutoff specifically defined for each assay [500 μg/L for ELISA and comparable assays (3)] are considered sufficient evidence to exclude a deep venous thrombosis or pulmonary emboli if the pretest probability is low (4). In addition, D-dimer has been shown to be a reliable indicator of coagulation activation in disseminated intravascular coagulation (5) and malignancy (6). More recently, the relevance of the determination of D-dimer in arterial disease was evaluated (7), and it was shown that D-dimer is a very good predictor of recurrent acute coronary syndromes after a first event (8). There is also some indication that the amount of D-dimer generated correlates to some extent with the degree of atherosclerosis (9). Fully quantitative D-dimer assays and their automation are recent improvements (10), and short turnaround times allow the routine use of such assays. Routinely, plasma is used for the D-dimer assays. Serum is believed not suitable because of the possibility of continued fibrinolytic activity, which (theoretically) could lead to a (falsely) increased D-dimer concentration. Here, we report that latex-enhanced immunoturbidimetric measurement allows the use of serum as a matrix for the measurement of D-dimer concentrations.
No takes yet. Share an insight, caveat, or question.
Korte et al. (2000) studied D-dimer determination. Latex-enhanced immunoturbidimetry in serum vs. Plasma was evaluated on D-dimer concentration measurement. Latex-enhanced immunoturbidimetric measurement allows the use of serum as a matrix for determining D-dimer concentrations.