Key result
A sequential algorithm using lead I and V1 vectors predicted the site of outflow tract ventricular arrhythmia origin with an overall accuracy of 72%.
Why the study?
Can standard 12-lead ECG criteria, specifically lead I, accurately distinguish the origin of outflow tract ventricular arrhythmias?
Observational (n=36)
Blinded observers
Can standard 12-lead ECG criteria, specifically lead I, accurately distinguish the origin of outflow tract ventricular arrhythmias?
A sequential ECG algorithm incorporating lead I and V1 criteria provides 72% accuracy in distinguishing the origin of outflow tract ventricular arrhythmias.
May aid ECG localization of outflow tract VA; leaves open prospective validation before clinical use.
INTRODUCTION: Outflow tract ventricular arrhythmia (OTVA) can be complicated to target for ablation when originating from either the periaortic or pulmonary valve (PV) region. Both sites may present with a small R wave in lead V1. However, the utility of lead I in distinguishing these arrhythmia locations is unknown. METHODS AND RESULTS: Thirty-six consecutive patients (mean age 41 ± 14 years, 13 male) underwent catheter ablation for OTVA. OTVA origin was determined from intracardiac electrogram tracings and electroanatomic maps. Observers blinded to results measured QRS waveform amplitude and duration from standard 12-lead ECG tracings. Measurements with highest diagnostic performance were modeled into an algorithm. Sites of successful ablation were anterior right ventricular outflow tract (RVOT; n = 6), posterior RVOT (n = 4), PV (n = 18), and right coronary cusp (RCC; n = 8). Highest performing surface ECG discriminators were from lead I to V1 vectors: RCC, lead I R wave ≥ 1.5 mV, and V1 R wave ≥2.0 mV (sensitivity 87%, specificity 93%); PV, V1 R wave > 0 mV, and lead I R/(R+S) ≤ 0.75 (sensitivity 78%, specificity 72%); anterior RVOT, V1 R wave = 0 mV, and lead I R/(R+S) <0.4 (sensitivity 67%, specificity 97%); posterior RVOT, V1 R wave > 0 mV, and lead I R/(R+S) > 0.75 (sensitivity 75%, specificity 84%). Sequential algorithmic application of these criteria resulted in an overall accuracy of 72% in predicting site of OTVA origin. CONCLUSIONS: A relatively large R wave in lead I is seen with RCC origin but not PV origin. A sequential algorithm has limited but potentially significant value beyond assessment of lead I in approaching OTVA.
No takes yet. Share an insight, caveat, or question.
Ebrille et al. (2013) conducted an observational in Outflow tract ventricular arrhythmia (OTVA) (n=36). 12-lead ECG (Lead I and V1 criteria) was evaluated on Overall accuracy in predicting site of OTVA origin using sequential algorithmic application of ECG criteria. A sequential algorithm using lead I and V1 vectors predicted the site of outflow tract ventricular arrhythmia origin with an overall accuracy of 72%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: