Key result
Increasing entrainment pacing current output from 10 mA to 20 mA paradoxically resulted in concealed fusion by selective right bundle capture, illustrating near-field inability to capture.
Why the study?
The authors sought to explain and illustrate the mechanism of paradoxical near-field inability to capture with increasing current strength during ventricular entrainment.
Case Report (n=1)
The case illustrates a paradoxical electrophysiological phenomenon where increasing pacing current strength leads to near-field inability to capture, resulting in selective far-field capture.
Answers are grounded in this paper and cite their sources.
Requires caution interpreting entrainment at higher outputs; hypothesis-generating for near- versus far-field capture dynamics in VT mapping.
We present a case of wide-complex tachycardia in which the clinical electrophysiological diagnosis was considered to be bundle branch re-entry ventricular tachycardia. A series of ventricular entrainment attempts were performed from the left and right ventricular septum to confirm the diagnosis. Entrainment pacing with a general current output (10 mA) was performed from the right ventricular septum with manifest fusion and a post-pacing interval similar to tachycardia cycle length. Thereafter, another entrainment attempt with a greater current output (20 mA) was performed from the same site. Paradoxically, concealed fusion was demonstrated by selective RB capture only, though there was no clear "RB" potential seen. In this case, we attempt to explain and illustrate the mechanism of paradoxical near-field inability to capture with increasing current strength.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2020) conducted a case report in Wide-complex tachycardia (bundle branch re-entry ventricular tachycardia) (n=1). Ventricular entrainment pacing was evaluated. Increasing entrainment pacing current output from 10 mA to 20 mA paradoxically resulted in concealed fusion by selective right bundle capture, illustrating near-field inability to capture.
Synapse has enriched 10 related papers. Consider them for comparative context: