Key result
Multifactorial prevention across the procedural pathway remains essential to reduce CIED infection risk.
Why the study?
Cardiac implantable electronic device infections are serious complications with substantial morbidity, mortality, and costs, making prevention a major priority in electrophysiology practice.
Does a structured, multifactorial preventive approach reduce cardiac implantable electronic device (CIED) infections in patients undergoing CIED procedures?
Does a structured, multifactorial preventive approach reduce cardiac implantable electronic device (CIED) infections in patients undergoing CIED procedures?
This comprehensive review underscores that preventing CIED infections relies on a structured, multi-step approach targeting modifiable risk factors and strict perioperative preventive measures rather than isolated interventions.
Emphasizes bundled perioperative prevention to reduce CIED infection morbidity; leaves open optimization via prospective trials in high-risk groups.
Background and Objectives: Cardiac implantable electronic device (CIED) infections remain among the most serious complications of pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy procedures. They are associated with substantial morbidity, mortality, prolonged hospitalization, system extraction, long-term antimicrobial therapy, and increased healthcare costs. As most infections arise from perioperative contamination or procedure-related complications, prevention has become a major priority in contemporary electrophysiology practice. This review aimed to summarize current evidence on the prevention of CIED infections, with particular emphasis on modifiable risk factors and perioperative preventive measures. Materials and Methods: A focused narrative review was undertaken using targeted searches of PubMed/MEDLINE and Scopus, supplemented by major international guideline and consensus documents, with priority given to contemporary guidelines, randomised trials, meta-analyses, and major observational studies relevant to CIED infection prevention. Results: Prevention of CIED infection requires a structured, multifactorial approach spanning the entire procedural pathway. Key preventive strategies include careful reassessment of device indication, individualized device selection, correction of modifiable risk factors, postponement of elective implantation in the presence of active infection, appropriate perioperative antibiotic prophylaxis, and optimized management of anticoagulant and antiplatelet therapy to minimize pocket hematoma. Additional relevant measures include meticulous skin antisepsis, limitation of temporary invasive devices and unnecessary hardware, appropriate venous access selection, careful generator pocket creation and wound closure, and avoidance of early reintervention whenever feasible. Antibacterial envelopes may reduce major CIED infections in selected high-risk patients, whereas routine escalation of preventive measures without proven benefit is not supported. Conclusions: CIED infection prevention is inherently multifactorial and depends on the consistent application of evidence-based measures before, during, and after device implantation. Rigorous control of modifiable risk factors, prevention of pocket hematoma, appropriate antimicrobial prophylaxis, and meticulous procedural technique remain the cornerstones of effective infection prevention in patients undergoing CIED procedures.
No takes yet. Share an insight, caveat, or question.
Rimkienė et al. (2026) conducted a review in Cardiac implantable electronic device (CIED) infections. Structured multifactorial perioperative preventive measures was evaluated. Structured multifactorial preventive measures, including modifiable risk factor control, pocket hematoma prevention, and appropriate antimicrobial prophylaxis, remain the cornerstones of effective CIED infection prevention.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: