Key result
CMR feature tracking based strain analysis is significantly more dependent on reader experience than conventional tagging, with inexperienced readers showing significant differences between modalities.
Why the study?
Does observer experience influence the reliability and accuracy of CMR feature tracking compared to CMR tagging for strain measurements in individuals with and without HFpEF?
Observational (n=38)
Blinded to own intermodality results and other readers' results
No
Does observer experience influence the reliability and accuracy of CMR feature tracking compared to CMR tagging for strain measurements in individuals with and without HFpEF?
The reliability and accuracy of CMR feature tracking for strain analysis are highly dependent on reader experience, requiring dedicated training to match the reference standard of CMR tagging.
Answers are grounded in this paper and cite their sources.
FT strain by inexperienced readers warrants caution in HFpEF; leaves open optimal training thresholds for tagging equivalence.
AIM: CMR quantitative myocardial strain analysis is increasingly being utilized in clinical routine. CMR feature tracking (FT) is now considered an alternative to the reference standard for strain assessment -CMR tagging. The impact of observer experience on the validity of FT results has not yet been investigated. The aim of this study was therefore to evaluate the observer experience-dependency of CMR FT and to compare results with the reference standard. METHODS: CSPAMM and SSFP-Cine sequences were acquired in 38 individuals (19 patients with HFpEF,19 controls) in identical midventricular short-axis locations. Global peak systolic circumferential strain (PSCS) together with LV ejection fraction (EF) and volumes were assessed by three observers (5,3 and 0 years of CMR-strain experience). Intermodality, intra- as well inter-observer variability were assessed. RESULTS: Correlation between tagging and FT derived PSCS depended on observer experience (r = 0.69, r = 0.58 and r = 0.53). For the inexperienced observer tagging and FT derived PSCS differed significantly (p = 0.0061). Intra-observer reproducibility of tagging derived PSCS were similar for all observers (coefficient of variation (CV): 6%, 6.8% and 4.9%) while reproducibility of FT derived PSCS (CV: 7.4%, 9.4% and 15.8%) varied depending on observer experience. Inter-observer reproducibility of tagging derived PSCS for observer 1 and 2 as well as 1 and 3 for tagging (CV: 6.17%, 9.18%) was superior in comparison to FT (CV: 11.8%, 16.4%). CONCLUSIONS: Reliability and accuracy of FT based strain analysis, more than tagging based strain analysis, is dependent on reader experience. CMR strain experience or dedicated training in strain evaluation is necessary for FT to deliver accurate strain data, comparable to that of CMR tagging.
No takes yet. Share an insight, caveat, or question.
Feißt et al. (2018) conducted an observational in Heart failure with preserved ejection fraction (HFpEF) and healthy controls (n=38). CMR Feature Tracking vs. CMR Tagging was evaluated on Peak systolic circumferential strain (PSCS) for inexperienced observer (r = 0.48, p=0.0061). CMR feature tracking based strain analysis is significantly more dependent on reader experience than conventional tagging, with inexperienced readers showing significant differences between modalities.
Synapse has enriched 10 related papers. Consider them for comparative context: