Key result
Later acrophase time linked to ~50% higher odds of poor sleep in CIED patients.
Why the study?
Poor sleep quality is a critical concern for patients with CIEDs, prompting an investigation into the relationship between sleep quality and circadian rest-activity patterns in these patients in Japan.
Cross-Sectional (n=54)
No
In patients with cardiac implantable electronic devices, a delayed peak in daily physical activity (acrophase time) is independently associated with poor self-reported sleep quality.
Answers are grounded in this paper and cite their sources.
Should not change practice in CIED patients; hypothesis-generating for circadian activity-sleep links needing prospective confirmation.
Background: Poor sleep quality is a critical concern for patients with cardiac implantable electronic devices (CIEDs). The aim of this study was to investigate the relationship between sleep quality and circadian rest-activity patterns in patients with CIEDs in Japan.
No takes yet. Share an insight, caveat, or question.
Ogishi et al. (2025) conducted a cross-sectional in Cardiac implantable electronic devices (CIEDs) (n=54). Acrophase time (circadian rest-activity pattern) was evaluated on Poor self-reported sleep quality (PSQI-J ≥6) (OR 1.503, 95% CI 1.020-2.215, p=0.039). A later acrophase time was independently associated with poor self-reported sleep quality in patients with cardiac implantable electronic devices.
Synapse has enriched 10 related papers. Consider them for comparative context: