Key result
Prolonged cardiac monitoring detects occult PAF in ~24% of cryptogenic stroke patients.
Why the study?
Does prolonged non-invasive cardiac monitoring detect occult paroxysmal atrial fibrillation in patients with cryptogenic stroke or TIA?
Observational (n=62)
No
Does prolonged non-invasive cardiac monitoring detect occult paroxysmal atrial fibrillation in patients with cryptogenic stroke or TIA?
Prolonged non-invasive cardiac monitoring detects occult paroxysmal atrial fibrillation in nearly 25% of patients with cryptogenic stroke, with frequent PVCs and multiple DWI signals serving as strong predictors.
Answers are grounded in this paper and cite their sources.
Supports prolonged monitoring to detect occult AF in cryptogenic stroke; leaves open effects on recurrence and need for RCTs.
Background and Purpose. Paroxysmal Atrial fibrillation/Flutter (PAF) detection rates in cryptogenic strokes have been variable. We sought to determine the percentage of patients with cryptogenic stroke who had PAF on prolonged non-invasive cardiac monitoring. Methods and Results. Sixty-two consecutive patients with stroke and TIA in a single center with a mean age of 61 (+/- 14) years were analyzed. PAF was detected in 15 (24%) patients. Only one patient reported symptoms of shortness of breath during the episode of PAF while on monitoring, and 71 (97%) of these 73 episodes were asymptomatic. A regression analysis revealed that the presence of PVCs (ventricular premature beats) lasting more than 2 minutes (OR 6.3, 95% CI, 1.11-18.92; P = .042) and strokes (high signal on Diffusion Weighted Imaging) (OR 4.3, 95% CI, 5-36.3; P = .041) predicted PAF. Patients with multiple DWI signals were more likely than solitary signals to have PAF (OR 11.1, 95% CI, 2.5-48.5, P < .01). Conclusion. Occult PAF is common in cryptogenic strokes, and is often asymptomatic. Our data suggests that up to one in five patients with suspected cryptogenic strokes and TIAs have PAF, especially if they have PVCs and multiple high DWI signals on MRI.
No takes yet. Share an insight, caveat, or question.
Bhatt et al. (2011) conducted an observational in Cryptogenic stroke or TIA (n=62). Presence of PVCs lasting more than 2 minutes vs. Absence of PVCs lasting more than 2 minutes was evaluated on Detection of paroxysmal atrial fibrillation (PAF) (OR 6.32, 95% CI 1.11-18.92, p=.042). Prolonged non-invasive cardiac monitoring detected occult paroxysmal atrial fibrillation in 24% of patients with cryptogenic stroke or TIA, with PVCs lasting >2 minutes strongly predicting its presence.