Key result
Flow-adjusted predicted PPM is not associated with increased 5-year mortality after TAVR.
Why the study?
Established methods for assessing predicted PPM do not consider flow status, potentially underestimating the rate and impact of PPM in patients with abnormal flow status.
Does flow status-based predicted prosthesis-patient mismatch increase the risk of adverse clinical outcomes in patients undergoing TAVR with balloon-expandable valves?
Cohort (n=1,510)
No
Does flow status-based predicted prosthesis-patient mismatch increase the risk of adverse clinical outcomes in patients undergoing TAVR with balloon-expandable valves?
Flow status-based predicted prosthesis-patient mismatch does not significantly increase the risk of mortality or structural valve deterioration up to 5 years after TAVR with balloon-expandable valves.
Answers are grounded in this paper and cite their sources.
Flow status-based predicted PPM showed no mortality link after TAVR; leaves open whether it refines risk stratification versus standard EOA methods.
Background: Effective orifice area (EOA) is flow dependent. However, established methods for the assessment of predicted prosthesis-patient mismatch (PPM) do not consider flow status and therefore may underestimate the rate and impact of PPM in patients with abnormal flow status. This study aimed to investigate the clinical impact of flow status-based predicted PPM in patients undergoing transcatheter aortic valve replacement (TAVR). Methods: ). Five-year mortality was comparable in patients with and without flow status-based predicted PPM defined by either method. These results were consistent when patients were stratified by flow status. Conclusions: Rates of PPM differ considerably when flow status is considered. There was no consistent signal of increased risk of adverse events up to 5 years in patients with flow status-based predicted PPM. Clinical Trial Registration: https://www.clinicaltrials.gov. NCT01368250.
No takes yet. Share an insight, caveat, or question.
Tomii et al. (2024) conducted a cohort in Severe, symptomatic aortic stenosis (n=1,510). Moderate or severe flow status-based predicted prosthesis-patient mismatch vs. No prosthesis-patient mismatch was evaluated on All-cause mortality at 5 years (HR 0.99, 95% CI 0.77-1.28, p=0.956). Moderate or severe flow status-based predicted prosthesis-patient mismatch was not associated with an increased risk of 5-year all-cause mortality (HR 0.99) compared to no mismatch in patients undergoing TAVR.
Synapse has enriched 10 related papers. Consider them for comparative context: