Key result
Atrial fibrillation catheter ablation was associated with a long-term decrease in total left atrial emptying fraction from 43% to 39% (p=0.001), which was inversely related to increased LA fibrosis.
Why the study?
The effects of AF catheter ablation on the left atrium are poorly understood.
Does atrial fibrillation catheter ablation affect left atrial structure and function as measured by CMR in patients with AF?
Cohort (n=51)
Does atrial fibrillation catheter ablation affect left atrial structure and function as measured by CMR in patients with AF?
AF catheter ablation acutely impairs LA function, but long-term functional changes depend on successful sinus rhythm restoration and the extent of ablation-induced fibrosis.
LAEF decline post-ablation warrants function monitoring in AF; leaves open impact on outcomes and ablation strategies.
BACKGROUND: The effects of atrial fibrillation (AF) catheter ablation on the left atrium (LA) are poorly understood. OBJECTIVES: To examine short- and long-term associations of AF catheter ablation with LA function using cardiac magnetic resonance (CMR). METHODS: Fifty-one AF patients (mean age 56 ± 8 years) underwent CMR at baseline, 1 day (n = 17) and 11 ± 2 months after ablation (n = 38). LA phasic volumes, emptying fractions (LAEF), and longitudinal strain were measured using feature-tracking CMR. LA fibrosis was quantified using late gadolinium enhancement (LGE). RESULTS: There were no acute changes in volume; however, active, total LAEF, and peak LA strain decreased significantly compared to the baseline. During long-term follow-up, there was a decrease in maximum but not minimum LA volume (from 99 ± 5.2 ml to 89 ± 4.7 ml; p = .009) and a decrease in total LAEF (from 43 ± 1.8% to 39 ± 2.0%; p = .001). In patients with AF recurrence, LA volumes were unchanged. However, total LAEF decreased from 38 ± 3% to 33 ± 3%; p = .015. Patients without AF recurrence had no changes in LA functional parameters during follow-up. The amount of LA LGE at long-term follow-up was higher compared to the baseline, however, was significantly less compared to immediately post-procedure (37 ± 1.9% vs. 47 ± 2.8%; p = .015). A higher increase in LA LGE extent compared to the baseline was associated with a greater decrease in total LAEF (r = -.59; p < .001). CONCLUSIONS: LA function is impaired acutely following AF catheter ablation. However, long-term changes of LA function are associated positively with the successful restoration of sinus rhythm and inversely with increased LA LGE.
No takes yet. Share an insight, caveat, or question.
Habibi et al. (2020) conducted a cohort in Atrial fibrillation (n=51). Catheter ablation vs. Baseline was evaluated on Total left atrial emptying fraction (LAEF) (p=0.001). Atrial fibrillation catheter ablation was associated with a long-term decrease in total left atrial emptying fraction from 43% to 39% (p=0.001), which was inversely related to increased LA fibrosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: