Why the study?
Intravascular catheterisation to measure cardiovascular relative pressure is limited by invasiveness, while non-invasive Doppler ultrasound estimates only apply to a range of constricted cardiovascular conditions.
Does the νWERP method using 4D flow MRI accurately estimate cardiovascular relative pressure compared to invasive catheterization in patients with complex congenital heart disease?
Does the νWERP method using 4D flow MRI accurately estimate cardiovascular relative pressure compared to invasive catheterization in patients with complex congenital heart disease?
The νWERP method using 4D flow MRI provides accurate, non-invasive estimation of cardiovascular relative pressure in complex anatomies, closely matching invasive catheter measurements.
Answers are grounded in this paper and cite their sources.
May support non-invasive pressure estimates in complex CHD; leaves open routine adoption pending larger prospective validation.
Many cardiovascular diseases lead to local increases in relative pressure, reflecting the higher costs of driving blood flow. The utility of this biomarker for stratifying the severity of disease has thus driven the development of methods to measure these relative pressures. While intravascular catheterisation remains the most direct measure, its invasiveness limits clinical application in many instances. Non-invasive Doppler ultrasound estimates have partially addressed this gap; however only provide relative pressure estimates for a range of constricted cardiovascular conditions. Here we introduce a non-invasive method that enables arbitrary interrogation of relative pressures throughout an imaged vascular structure, leveraging modern phase contrast magnetic resonance imaging, the virtual work-energy equations, and a virtual field to provide robust and accurate estimates. The versatility and accuracy of the method is verified in a set of complex patient-specific cardiovascular models, where relative pressures into previously inaccessible flow regions are assessed. The method is further validated within a cohort of congenital heart disease patients, providing a novel tool for probing relative pressures in-vivo.
No takes yet. Share an insight, caveat, or question.
Marlevi et al. (2019) studied this question.