Why the study?
Para-aortic adipose tissue is linked to aortic atherosclerosis and enlargement, but its relationship with ascending aortic width when measured using transthoracic echocardiography had not been investigated.
Is para-aortic adipose tissue (PAT) thickness measured by transthoracic echocardiography associated with ascending aortic dilatation in adult cardiology outpatients?
Is para-aortic adipose tissue (PAT) thickness measured by transthoracic echocardiography associated with ascending aortic dilatation in adult cardiology outpatients?
Para-aortic adipose tissue thickness measured by routine transthoracic echocardiography is independently associated with ascending aortic dilatation and may serve as an accessible imaging biomarker for aortic risk.
PAT thickness on TTE was associated with AAD; leaves open incremental value and requires prospective validation before clinical use.
Background Para-aortic adipose tissue (PAT) is the local adipose tissue that externally surrounds the aorta. It contributes significantly to aortic atherosclerosis and enlargement. Studies conducted with computed tomography and magnetic resonance have shown that individuals with aortic aneurysm had more PAT than healthy individuals. In this study, we measured PAT using transthoracic echocardiography (TTE). The aim of this study is to investigate the possible relationship of TTE measured PAT with ascending aortic width.Methods PAT was defined as the hypoechoic space in front of ascending aortic 2 cm above the sinotubular junction at the end of the systole. Patients were divided into 2 groups according to the presence of dilatation in the ascending aorta using Roman’s classification (aortic size index, ASI). ASI of less than 21 was considered no aortic dilation and an ASI of 21 mm/m2 or greater was considered to have aortic dilation.Results A total of 321 unselected patients were divided into the ascending aortic dilatation (AAD) group (n = 96) and the normal ascending aorta diameter group (n = 225 patients). PAT was significantly higher in the AAD group compared with the non-ADD group (0.9 (0.48) vs. 0.7 (0.91) mm, p < 0.0001). Univariate and multivariate logistic regression analysis revealed that PAT (OR: 3.005, 95%CI (1.445–6.251)) were significantly associated with AAD.Conclusions This is the first study which evaluated PAT measured by TTE. We found a significant association between PAT measured by TTE and ascending aorta width.
No takes yet. Share an insight, caveat, or question.
Adar et al. (2022) studied this question.