Why the study?
Respiratory motion adjustment is recommended during automated RF annotation-guided PVI, but lacks in vivo validation.
Does respiratory motion adjustment (RMA) alter the accuracy of automated RF annotation during pulmonary vein isolation in patients under general anesthesia?
Does respiratory motion adjustment (RMA) alter the accuracy of automated RF annotation during pulmonary vein isolation in patients under general anesthesia?
Respiratory motion adjustment (RMA) delays the identification of deliberate catheter motion during left atrial posterior wall RF delivery, suggesting operators should avoid RMA use for greater accuracy during auto-annotated RF delivery.
BACKGROUND: During automated radiofrequency (RF) annotation-guided pulmonary vein isolation (PVI), respiratory motion adjustment (RMA) is recommended, yet lacks in vivo validation. METHODS: Following contact force (CF) PVI (continuous RF, 30 W) using general anesthesia and automated RF annotation-guidance (VISITAG™: force-over-time 100% minimum 1 g; 2 mm position stability; ACCURESP™ RMA "off") in 25 patients, we retrospectively examined RMA settings "on" versus "off" at the left atrial posterior wall (LAPW). RESULTS: Respiratory motion detection occurred in eight, permitting offline retrospective comparison of RMA settings. Significant differences in LAPW RF auto-annotation occurred according to RMA setting, with curves displaying catheter position, CF and impedance data indicating "best-fit" for catheter motion detection using RMA "off." Comparing RMA "on" versus "off," respectively: total annotated sites, 82 versus 98; median RF duration per-site, 13.3 versus 10.6 s (p < 0.0001); median force time integral 177 versus 130 gs (p = 0.0002); mean inter-tag distance (ITD), 6.0 versus 4.8 mm (p = 0.002). Considering LAPW annotated site 1-to-2 transitions resulting from deliberate catheter movement, 3 concurrent with inadvertent 0 g CF demonstrated < 0.6 s difference in RF duration. However, 13 deliberate catheter movements during constant tissue contact (ITD range: 2.1-7.0 mm) demonstrated (mean) site-1 RF duration difference 3.7 s (range: -1.3 to 11.3 s): considering multiple measures of catheter position instability, the appropriate indication of deliberate catheter motion occurred with RMA "off" in all. CONCLUSIONS: ACCURESP™ respiratory motion adjustment importantly delayed the identification of deliberate and clinically relevant catheter motion during LAPW RF delivery, rendering auto-annotated RF display invalid. Operators seeking greater accuracy during auto-annotated RF delivery should avoid RMA use.
No takes yet. Share an insight, caveat, or question.
Tomlinson et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: