Why the study?
Does nongated 128-slice dual-source CT reduce contrast media, radiation dose, and scan duration compared to ECG-gated 64-slice MDCT in patients undergoing pulmonary vein isolation?
Does nongated 128-slice dual-source CT reduce contrast media, radiation dose, and scan duration compared to ECG-gated 64-slice MDCT in patients undergoing pulmonary vein isolation?
Nongated 128-slice dual-source CT provides sufficient image quality for electroanatomical mapping during AF ablation while significantly reducing contrast volume, radiation exposure, and scan time compared to 64-slice MDCT.
Favors nongated 128-DSCT for pre-PVI CT to cut contrast and radiation; confirms preserved quality versus gated 64-MDCT in RCT.
INTRODUCTION: Using a high-pitch dual-source CT (DSCT), we aimed to quantify the amounts of contrast media, radiation doses, and image qualities in patients undergoing pulmonary vein (PV) isolation. METHODS AND RESULTS: The study enrolled 60 patients who were randomly assigned in a 1: 1: 1 ratio to undergo ECG-gated 64-slice multidetector computed tomography (MDCT; group I, n = 20), ECG-gated 128-DSCT (group II, n = 20), and nongated 128-DSCT (group III, n = 20). The total amount of contrast media was lower in groups II and III compared with group I (I: 54.7 ± 5.6, II: 26.6 ± 2.7, and III: 28.7 ± 6.9 mL, P < 0.001). The CT dose index was lower in groups II and III compared with group I (I: 73.1 ± 5.2, II: 3.5 ± 0.1, and III: 3.7 ± 0.1 mGy, P < 0.001). The dose length product was lower in groups II and III compared with group I (I: 1154.8 ± 82.8, II: 75.4 ± 2.3, and III: 77.2 ± 1.9 mGy × cm, P < 0.001). The total CT effective radiation dose was lower in groups II and III compared with group I (I: 16.2 ± 1.2, II: 1.1 ± 0.1, and III: 1.1 ± 0.1 mSv, P < 0.001). The total CT scan duration was shorter in group III compared with groups I and II (I: 30.8 ± 2.2, II: 23.4 ± 3.6, and III: 16.0 ± 2.4 minutes, P < 0.001). There were no significant differences in quality for integrated electroanatomical mapping (EAM) and parameters associated with PV isolation among the 3 groups. CONCLUSION: Nongated 128-DSCT provides sufficient image quality to allow integrated EAM while exposing the patient to less contrast media, lower radiation doses, and shorter CT scan durations.
No takes yet. Share an insight, caveat, or question.
Iwayama et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: