A simple system has been developed to identify patients with upper gastrointestinal tract haemorrhage who run a high risk of continued bleeding or rebleeding. The system is based on six items of patient data available at or soon after arrival in hospital. It was evaluated in a prospective study of 66 patients with upper gastrointestinal tract haemorrhage. Over half of the patients classified by the system into a high-risk category either continued bleeding or rebled after apparent cessation (as against one out of 33 patients in the low-risk category). The high-rish group also had a higher mortality (21%) than those in the low-risk group (nil). The addition or subtraction of early endoscopic findings made little difference to the accuracy of prognosis.
No takes yet. Share an insight, caveat, or question.
Morgan et al. (1977) studied this question.