Why the study?
To propose a method for estimating absolute left ventricular pressure and its maximum rate of rise from epicardial accelerometer data using machine learning.
Does machine learning-based analysis of epicardial accelerometer data accurately estimate absolute left ventricular pressure and its first derivative in a porcine model?
Does machine learning-based analysis of epicardial accelerometer data accurately estimate absolute left ventricular pressure and its first derivative in a porcine model?
Machine learning applied to epicardial accelerometer data can reliably estimate absolute left ventricular pressure and its first derivative in a preclinical porcine model.
Answers are grounded in this paper and cite their sources.
Preclinical accuracies support ML-based LV pressure estimation in research models; leaves open human validation before any clinical consideration.
Objective: A method to estimate absolute left ventricular (LV) pressure and its maximum rate of rise (LV dP/dtmax) from epicardial accelerometer data and machine learning is proposed. Methods: Five acute experiments were performed on pigs. Custom-made accelerometers were sutured epicardially onto the right ventricle, LV, and right atrium. Different pacing configurations and contractility modulations, using isoflurane and dobutamine infusions, were performed to create a wide variety of hemodynamic conditions. Automated beat-by-beat analysis was performed on the acceleration signals to evaluate amplitude, time, and energy-based features. For each sensing location, bootstrap aggregated classification tree ensembles were trained to estimate absolute maximum LV pressure (LVPmax) and LV dP/dtmax using amplitude, time, and energy-based features. After extraction of acceleration and pressure-based features, location specific, bootstrap aggregated classification ensembles were trained to estimate absolute values of LVPmax and its maximum rate of rise (LV dP/dtmax) from acceleration data. Results: With a dataset of over 6,000 beats, the algorithm narrowed the selection of 17 predefined features to the most suitable 3 for each sensor location. Validation tests showed the minimal estimation accuracies to be 93% and 86% for LVPmax at estimation intervals of 20 and 10 mmHg, respectively. Models estimating LV dP/dtmax achieved an accuracy of minimal 93 and 87% at estimation intervals of 100 and 200 mmHg/s, respectively. Accuracies were similar for all sensor locations used. Conclusion: Under pre-clinical conditions, the developed estimation method, employing epicardial accelerometers in conjunction with machine learning, can reliably estimate absolute LV pressure and its first derivative.
No takes yet. Share an insight, caveat, or question.
Westphal et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: