Key result
Miniature epicardial accelerometer tracks LV dP/dtmax with strong correlation in preclinical testing.
Why the study?
An implantable epicardial accelerometer has potential as a sensor of myocardial function, but its correlation with myocardial contractility needed evaluation.
Does radial epicardial acceleration measured by a miniature accelerometer correlate with LV dP/dtmax in an animal model?
Does radial epicardial acceleration measured by a miniature accelerometer correlate with LV dP/dtmax in an animal model?
Radial epicardial acceleration measured by a miniature accelerometer correlates strongly with LV dP/dtmax, suggesting its potential as a continuous sensor of myocardial function.
Previous studies have indicated that endocardial acceleration correlates with myocardial contractility. An implantable epicardial accelerometer has potential as a sensor of myocardial function. We hypothesized that radial epicardial acceleration would correlate with the maximum rate of left ventricular pressure change (LV dP/dtmax), an indicator of myocardial contractility, over a range of myocardial contractile states. Radial epicardial acceleration was defined as the difference in the peak positive to peak negative acceleration of the left ventricular epicardial surface during a cardiac cycle. Measurements of radial epicardial acceleration were made in 4 anesthetized mongrel dogs. A range of myocardial contractile states was realized with intravenous infusion of esmolol and dobutamine. A miniature, uniaxial accelerometer (PCB Piezotronics, Inc.) was fixed on the anterior epicardial surface of the left ventricle midway between the atrioventricular groove and the apex. Left ventricular pressure was measured with a pressure transducer and LV dP/dtmax was calculated. Calculated LV dP/dtmax ranged from 400 to 14,900 mm Hg/sec. Radial epicardial acceleration ranged from 0.3 to 7.8 g (1 g = 9.81 m/sec2). The linear regression coefficient between radial epicardial acceleration and LV dP/dtmax was 0.92 (p < 0.0001). Radial epicardial acceleration correlates well with LV dP/dtmax, a known measure of myocardial contractility. Measurement of left ventricular epicardial acceleration with an implantable accelerometer has potential application as a continuous sensor of myocardial function.
No takes yet. Share an insight, caveat, or question.
Helman et al. (2000) studied this question. Miniature epicardial accelerometer vs. LV dP/dtmax (pressure transducer) was evaluated on Correlation between radial epicardial acceleration and LV dP/dtmax (linear regression coefficient 0.92, p=< 0.0001). Radial epicardial acceleration measured by a miniature accelerometer strongly correlated with LV dP/dtmax (linear regression coefficient 0.92, p < 0.0001) in an experimental dog model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: