Key result
The stand-alone Cox-Maze IV procedure achieved 94%, 83%, and 88% freedom from atrial tachyarrhythmias at 1, 5, and 7 years in patients with longstanding persistent atrial fibrillation.
Why the study?
There have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF undergoing the Cox-Maze IV procedure.
Does the stand-alone Cox-Maze IV procedure prevent atrial tachyarrhythmia recurrence in patients with longstanding persistent atrial fibrillation?
Cohort (n=174)
Does the stand-alone Cox-Maze IV procedure prevent atrial tachyarrhythmia recurrence in patients with longstanding persistent atrial fibrillation?
The stand-alone Cox-Maze IV procedure demonstrates excellent long-term efficacy for maintaining sinus rhythm in patients with longstanding persistent AF, even after failed catheter ablation.
Supports long-term arrhythmia freedom after stand-alone Cox-Maze IV in longstanding persistent AF; leaves open randomized confirmation versus ablation.
INTRODUCTION: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox-Maze IV procedure (CMP-IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat. METHODS AND RESULTS: Between May 2003 and March 2020, 174 consecutive patients underwent a stand-alone CMP-IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine-Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0-12.0 years), with 71% (124/174) having failed at least one prior catheter-based ablation. There were no 30-day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence. CONCLUSION: Despite the majority of patients having a long-duration of preoperative AF and having failed at least one catheter-based ablation, the stand-alone CMP-IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand-alone CMP-IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.
No takes yet. Share an insight, caveat, or question.
McGilvray et al. (2021) conducted a cohort in longstanding persistent atrial fibrillation (n=174). stand-alone Cox-Maze IV procedure (CMP-IV) was evaluated on Freedom from atrial tachyarrhythmias (ATAs) at 1 year. The stand-alone Cox-Maze IV procedure achieved 94%, 83%, and 88% freedom from atrial tachyarrhythmias at 1, 5, and 7 years in patients with longstanding persistent atrial fibrillation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: