Prior studies on AS echocardiographic reproducibility had limitations such as outdated equipment or lack of test-retest designs, and the impact of reproducibility on recent guideline-based AS grading had not been described.
Echocardiographic grading of moderate aortic stenosis has significant interobserver variability, particularly for aortic valve area, leading to discordant severity classification in nearly a quarter of patients.
Answers are grounded in this paper and cite their sources.
Echocardiographic AS grading warrants clinical caution given interobserver discordance; leaves open the need for standardized protocols to improve reproducibility.
Echocardiography is the first-line modality for serial assessments of aortic stenosis (AS), in which peak aortic velocity (AVpeak), mean pressure gradient (AVmean), dimensionless index (velocity-time integral [VTI] in the left ventricular outflow tract [VTILVOT]/VTI of the transaortic Doppler tracing [VTIAV]), and aortic valve area (AVA) are most commonly used.1Baumgartner H. Hung J. Bermejo J. et al.Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European association of cardiovascular imaging and the American society of echocardiography.J Am Soc Echocardiogr. 2017; 30: 372-392Abstract Full Text Full Text PDF PubMed Scopus (669) Google Scholar Knowledge of reproducibility of these parameters in terms of acquisition and measurements is of great importance to understand to what degree the acquisition is observer dependent and to determine whether a true change has occurred.2Bunting K.V. Steeds R.P. Slater L.T. et al.A practical guide to assess the reproducibility of echocardiographic measurements.J Am Soc Echocardiogr. 2019; 32: 1505-1515Abstract Full Text Full Text PDF PubMed Scopus (87) Google Scholar Previous studies are either limited by being performed on outdated echocardiographic equipment,3Otto C.M. Pearlman A.S. Comess K.A. et al.Determination of the stenotic aortic valve area in adults using Doppler echocardiography.J Am Coll Cardiol. 1986; 7: 509-517Crossref PubMed Scopus (353) Google Scholar,4Geibel A. Görnandt L. Kasper W. et al.Reproducibility of Doppler echocardiographic quantification of aortic and mitral valve stenoses: comparison between two echocardiography centers.Am J Cardiol. 1991; 67: 1013-1021Abstract Full Text PDF PubMed Scopus (58) Google Scholar small sample sizes,3Otto C.M. Pearlman A.S. Comess K.A. et al.Determination of the stenotic aortic valve area in adults using Doppler echocardiography.J Am Coll Cardiol. 1986; 7: 509-517Crossref PubMed Scopus (353) Google Scholar lack of detailed information on whether different observers could freely choose which images to use5Moura L.M. Ramos S.F. Pinto F.J. et al.Analysis of variability and reproducibility of echocardiography measurements in valvular aortic valve stenosis.Rev Port Cardiol. 2011; 30: 25-33PubMed Google Scholar or not performed with a test-retest design. Importantly, it has not been previously described how reproducibility can affect AS severity grading according to recent echocardiographic guidelines.1Baumgartner H. Hung J. Bermejo J. et al.Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European association of cardiovascular imaging and the American society of echocardiography.J Am Soc Echocardiogr. 2017; 30: 372-392Abstract Full Text Full Text PDF PubMed Scopus (669) Google Scholar,6Vahanian A. Beyersdorf F. Praz F. et al.2021 ESC/EACTS Guidelines for the management of valvular heart disease.Eur Heart J. 2021; 43: 561-632Crossref Scopus (1924) Google Scholar We aimed to evaluate the acquisition and measurement reproducibility of echocardiographic assessment of moderate AS and to determine how this may affect AS grading. Two data sets (n = 100) of patients with moderate AS (>3.0 to <4.0 m/sec) were initially included in this study, of which 70 were retrospectively identified in the administrative database at Växjö Central Hospital, Växjö, Sweden, from a set starting date and consecutively included dating backward. These patients had undergone a comprehensive echocardiography by an experienced sonographer in line with current recommendations.1Baumgartner H. Hung J. Bermejo J. et al.Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European association of cardiovascular imaging and the American society of echocardiography.J Am Soc Echocardiogr. 2017; 30: 372-392Abstract Full Text Full Text PDF PubMed Scopus (669) Google Scholar To determine test-retest variability, 30 patients were prospectively included among clinically referred patients. A standard, comprehensive echocardiography investigation of a patient with AS was performed by an experienced investigator, including right parasternal Doppler acquisitions.1Baumgartner H. Hung J. Bermejo J. et al.Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European association of cardiovascular imaging and the American society of echocardiography.J Am Soc Echocardiogr. 2017; 30: 372-392Abstract Full Text Full Text PDF PubMed Scopus (669) Google Scholar The LVOT diameter was measured at the annular level, that is, at the hinge points of valvular insertions.7Guzzetti E. Capoulade R. Tastet L. et al.Estimation of stroke volume and aortic valve area in patients with aortic stenosis: a comparison of echocardiography versus cardiovascular magnetic resonance.J Am Soc Echocardiogr. 2020; 33: 953-963.e5Abstract Full Text Full Text PDF PubMed Scopus (22) Google Scholar The examination was immediately followed by an additional focused echocardiogram (left ventricular volumes, Doppler tracing across the aortic valve [apical and right parasternal views] and LVOT, and LVOT diameter) by a second investigator blinded to the first recordings. Patients with irregular rhythm or inability to give informed consent (prospective cohort) were excluded. One patient was excluded due to missing recordings in the repeat examination. Two experienced observers independently and blinded to the clinical report measured AVpeak, AVmean, VTILVOT, LVOT diameter, and left ventricular ejection fraction (LVEF), choosing freely, to resemble clinical reality, which image and tracing to use. In addition, 1 observer performed the same measurements on the retest examination for assessment of acquisition reproducibility. Among the 99 patients, mean AVpeak was 3.5 ± 0.3 m/sec, AVmean was 29 ± 6 mm Hg, dimensionless index was 0.24 ± 0.06, and AVA was 1.1 ± 0.3 cm2. Mean LVEF was 60% ± 8%, and 16% had LVEF <50%. A right parasternal view was used for detection of the peak velocity by observer 1 and observer 2 in 33% and 34% of cases, respectively. Mean differences, coefficient of variation, and repeatability coefficients are presented for the 2 observers and for the test-retest setting in Table 1 and for patients with normal LVEF separately in the Supplemental Material. Scatterplots are presented in Supplemental Figure 1. AVpeak had the lowest test-retest and interobserver variability, while the largest variability was observed for AVA in both settings. The observed interobserver acquisition reproducibility indicated that the difference could be as much as 0.4 m/sec for AVpeak, 8 mm Hg for AVmean, 0.13 for dimensionless index, and 0.56 cm2 for AVA. The coefficients of variation were similar among the 3 constituents of AVA suggesting that the combination of multiple measurements contributes to the large variability. Variability was substantially lower for all measures when the 2 observers performed measurements on the same images in the patients in the test-retest subset (Table 1). This suggests that variability in acquisition is an important element in variability in repeated examinations.Table 1Reproducibility for measurements of AS severity (AVpeak, AVmean, dimensionless index, and AVA)Interobserver acquisition reproducibility, test-retest variability (2 observers, different same-day examinations), n = 29Difference∗Both absolute differences and repeatability coefficients are presented in the relevant measurement units, i.e., m/sec for AVpeak, mm Hg for AVmean, and cm2 for AVA.Coefficient of variation, % [95% CI]Repeatability coefficient∗Both absolute differences and repeatability coefficients are presented in the relevant measurement units, i.e., m/sec for AVpeak, mm Hg for AVmean, and cm2 for AVA.Peak velocity, m/sec0.00 ± 0.216.2 [3.8-8.6]0.41AVmean, mm Hg0.8 ± 3.412.4 [7.8-17.3]6.8Dimensionless index, unitless0.00 ± 0.0417.9 [10.9-24.9]0.08AVA, cm20.04 ± 0.2628.3 [17.2-39.3]0.52 LVOT diameter, cm0.1 ± 0.28.7 [5.3-12.1]0.4 VTILVOT, cm0.2 ± 2.411.5 [7.0-16.0]4.8 VTIAV, cm1.1 ± 6.38.1 [4.9-11.2]12.3Interobserver variability for measurements of AS (AVpeak, AVmean, dimensionless index, and AVA) using the same curves/images for measurements, n = 29Peak velocity, m/sec0.04 ± 0.103.5 [2.5-4.6]0.20AVmean, mm Hg0.5 ± 1.96.8 [4.8-8.8]3.7Dimensionless index, unitless0.03 ± 0.026.2 [3.8-8.6]0.04AVA, cm20.00 ± 0.1718.0 [12.7-23.1]0.33 LVOT diameter, cm0.0 ± 0.27.7 [5.4-9.9]0.3 VTILVOT, cm0.5 ± 1.05.6 [3.9-7.2]1.9 VTIAV, cm0.2 ± 2.02.7 [1.9-3.5]4.0Interobserver measurement reproducibility (2 observers, same examination, images freely chosen), n = 99Peak velocity, m/sec0.07 ± 0.195.3 [4.3-6.4]0.36AVmean, mm Hg1.2 ± 3.110.5 [8.4-12.6]6.0Dimensionless index, unitless0.00 ± 0.0311.3 [9.0-13.5]0.05AVA, cm20.04 ± 0.1919.7 [15.8-23.7]0.38 LVOT diameter, cm0.1 ± 0.27.7 [6.1-9.2]0.3 VTILVOT, cm0.0 ± 1.78.9 [7.1-10.7]3.3 VTIAV, cm0.5 ± 5.06.3 [5.1-7.6]9.795% CI, 95% confidence interval.Absolute measurement differences presented as mean ± SD. Coefficient of variation is defined as SD of the differences between observer measurements/mean of observer measurements × 100. Repeatability coefficient is defined as 1.96 × SD of the differences between observer measurements.∗ Both absolute differences and repeatability coefficients are presented in the relevant measurement units, i.e., m/sec for AVpeak, mm Hg for AVmean, and cm2 for AVA. Open table in a new tab 95% CI, 95% confidence interval. Absolute measurement differences presented as mean ± SD. Coefficient of variation is defined as SD of the differences between observer measurements/mean of observer measurements × 100. Repeatability coefficient is defined as 1.96 × SD of the differences between observer measurements. In the recommended algorithm to determine AS severity,6Vahanian A. Beyersdorf F. Praz F. et al.2021 ESC/EACTS Guidelines for the management of valvular heart disease.Eur Heart J. 2021; 43: 561-632Crossref Scopus (1924) Google Scholar the presence of a high-gradient (AVpeak ≥4 m/sec, AVmean ≥40 mm Hg) or low-gradient AS is determined. In low-gradient AS, AVA (AVA >1 cm2 = moderate AS) and the flow status based on body size–adjusted stroke volume are assessed (normal flow [>35 mL/m2] = “severe AS unlikely”). In low-flow status further evaluation with a dobutamine stress test is recommended if LVEF <50%, and an integrated approach if LVEF ≥50%. When this algorithm was applied (n = 99), agreement between observers was only moderate (Kappa value, 0.45; 73% agreement; Table 2. In 18 of 27 cases (67%), disagreement in classification was based on differences in AVA. In total, almost one-fourth of patients were classified differently based on measurement differences on the same examination. Reproducibility was worse for AVA measurements compared with Doppler measurements, in line with previous reports of interobserver variability of echocardiographic assessment of AS.3Otto C.M. Pearlman A.S. Comess K.A. et al.Determination of the stenotic aortic valve area in adults using Doppler echocardiography.J Am Coll Cardiol. 1986; 7: 509-517Crossref PubMed Scopus (353) Google Scholar, 4Geibel A. Görnandt L. Kasper W. et al.Reproducibility of Doppler echocardiographic quantification of aortic and mitral valve stenoses: comparison between two echocardiography centers.Am J Cardiol. 1991; 67: 1013-1021Abstract Full Text PDF PubMed Scopus (58) Google Scholar, 5Moura L.M. Ramos S.F. Pinto F.J. et al.Analysis of variability and reproducibility of echocardiography measurements in valvular aortic valve stenosis.Rev Port Cardiol. 2011; 30: 25-33PubMed Google Scholar,8Sacchi S. Dhutia N.M. Shun-Shin M.J. et al.Doppler assessment of aortic stenosis: a 25-operator study demonstrating why reading the peak velocity is superior to velocity time integral.Eur Heart J Cardiovasc Imaging. 2018; 19: 1380-1389Crossref PubMed Scopus (18) Google Scholar Repeatability coefficients were especially large for AVA, making either AVpeak or AVmean the most suitable measure when assessing serial examinations. Given the limitations of reproducibility, vigilance is needed when measurements are bordering severity cutoffs, and a second examiner should be engaged, if possible, to improve interpretability.Table 2Agreement in classification based on the algorithmic approach recommended by European Society of Cardiology and European Association for Cardio-Thoracic Surgery when applied to all patients based on measurements performed on the same examination with images freely chosenObserver 1Moderate AS∗Moderate AS and severe AS unlikely are considered as the same classification.Integrated approachDobutamine stress testSevere ASObserver 2 Moderate AS∗Moderate AS and severe AS unlikely are considered as the same classification.65113 Integrated approach14622 Dobutamine stress test2010 Severe AS1000Kappa value, 0.45 [0.29-0.60]. Green fields denote cases with agreement (72 [73%]) between observers. Disagreement occurred in 27 cases (27%). Red fields denote disagreement due to differences in AVA (16 [67%]), blue fields differences in AVpeak (6 [22%]), and yellow fields differences in LVEF (2 [7%]).∗ Moderate AS and severe AS unlikely are considered as the same classification. Open table in a new tab Kappa value, 0.45 [0.29-0.60]. Green fields denote cases with agreement (72 [73%]) between observers. Disagreement occurred in 27 cases (27%). Red fields denote disagreement due to differences in AVA (16 [67%]), blue fields differences in AVpeak (6 [22%]), and yellow fields differences in LVEF (2 [7%]). The data underlying this article can be shared upon reasonable request to the corresponding author. None. .Supplemental Table 1Reproducibility for measurements of AS severity (AVpeak, AVmean, dimensionless index, and AVA [and its constituents]) in patients with normal LVEF onlyInterobserver measurement reproducibility (2 observers, same examination, images freely chosen), n = 86Difference∗Both absolute differences and repeatability coefficients are presented in the relevant measurement units, that is, m/sec for AVpeak, mm Hg for mean pressure gradient, and cm2 for AVA.Coefficient of variation, % [95% CI]Repeatability coefficient∗Both absolute differences and repeatability coefficients are presented in the relevant measurement units, that is, m/sec for AVpeak, mm Hg for mean pressure gradient, and cm2 for AVA.AVpeak, m/sec0.07 ± 0.185.2 [4.0-6.3]0.35AVmean, mm Hg1.3 ± 3.110.6 [8.3-12.9]6.1Dimensionless index, unitless0.00 ± 0.0211.4 [8.9-13.9]0.06AVA, cm20.04 ± 0.1919.8 [15.5-24.1]0.39 LVOT diameter, cm0.1 ± 0.27.8 [6.1-9.5]0.3 VTILVOT, cm0.0 ± 1.89.0 [7.1-11.0]3.4 VTIAV, cm0.6 ± 4.86.1 [4.8-7.5]9.5Absolute measurement differences are presented as mean ± SD. Coefficient of variation is defined as SD of the differences between observer measurements/mean of observer measurements × 100. Repeatability coefficient is defined as 1.96 × SD of the differences between observer measurements.∗ Both absolute differences and repeatability coefficients are presented in the relevant measurement units, that is, m/sec for AVpeak, mm Hg for mean pressure gradient, and cm2 for AVA. Open table in a new tab Absolute measurement differences are presented as mean ± SD. Coefficient of variation is defined as SD of the differences between observer measurements/mean of observer measurements × 100. Repeatability coefficient is defined as 1.96 × SD of the differences between observer measurements.
No takes yet. Share an insight, caveat, or question.
Manna et al. (2023) studied this question.