Why the study?
A retrograde transaortic access might be limited in mapping and ablation for some LV arrhythmias, prompting evaluation of the feasibility and safety of a transseptal approach for catheter ablation of LV aneurysm-related ischemic VT.
Does a transseptal approach with a steerable sheath improve ablation success and safety in patients with LVA-related VT who failed a transaortic approach?
Does a transseptal approach with a steerable sheath improve ablation success and safety in patients with LVA-related VT who failed a transaortic approach?
A transseptal approach with a steerable sheath is a feasible, safe, and effective alternative for catheter ablation of LVA-related VT when the transaortic approach fails.
Answers are grounded in this paper and cite their sources.
Should not yet change practice for LVA-VT ablation; leaves open role of transseptal access pending larger studies.
Background: A retrograde transaortic access might be limited in mapping and ablation for some left ventricular (LV) arrhythmias. We examined the feasibility and safety of a transseptal approach for catheter ablation of LV aneurysm (LVA)-related ischemic ventricular tachycardia (VT). Subjects and Methods: Five consecutive patients with postinfarction LVA-related VT were selected for catheter ablation at Fuwai Hospital from April 2011 to October 2015 in this retrospective study. After a routine transaortic LV-mapping approach was failed, a transseptal approach with a steerable sheath was performed in all these cases. The study was approved by the Ethics Committee of Fuwai Cardiovascular Hospital (approval No. 2016-768) on May 24, 2016. Results: In these five patients, four had LVAs located in the LV apical area, and one in the septum. Acute ablation successes were all failed to achieve through the transaortic route. Two were due to aortic stenosis and tortuous peripheral arteries and the others were due to failure to target the effective sites. While all ablation procedures succeeded through the sequent transseptal approach with a steerable sheath, and no major complications related to the transseptal approach were reported. During the 12-month (10–12 months) follow-up, no electrical storm or episode of VT was documented. One VT recurrence occurred, yet acute success was obtained again through the transseptal approach. Conclusions: Transseptal approach appears a feasible, safe, and effective method in catheter ablation for VT with LVA and could be considered as an elective approach.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: