Why the study?
Does cardiac MRI using an open 1.0T MR platform provide comparable image quality and better tolerance compared to a cylindrical 1.5T MR system in healthy volunteers?
Does cardiac MRI using an open 1.0T MR platform provide comparable image quality and better tolerance compared to a cylindrical 1.5T MR system in healthy volunteers?
Cardiac MRI using an open 1.0T platform provides comparable image quality to a standard 1.5T cylindrical scanner while significantly improving patient tolerance.
Answers are grounded in this paper and cite their sources.
Open 1.0T CMR may improve tolerance with comparable quality in volunteers; leaves open validation in patients before clinical use.
Background: Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients. The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. Material/Method: Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers’ tolerance to examinations in both scanners was investigated. Results: SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). Conclusions: Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.
No takes yet. Share an insight, caveat, or question.
Fischbach et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: