Answers are grounded in this paper and cite their sources.
This randomized trial tests a new acoustic emission sensor design using lead-free ceramics to improve sensitivity and resonance in high-voltage equipment.
Resonant acoustic emission (AE) sensors for high‐voltage equipment typically rely on lead‐based ceramics. This study optimizes the diameter‐to‐thickness ( D / T ) ratio of lead‐free (Na 0.51 K 0.47 Li 0.02 )(Nb 0.8 Ta 0.2 )O 3 (NKLNT) ceramics for low‐frequency AE sensing. NKLNT disks ( D = 12 mm, D / T = 1.5–6.0) were evaluated in the 100–300 kHz range. At D / T = 2.0, the ceramic exhibits the highest planar coupling ( k p = 0.609) and stable resonance behavior with a Curie temperature of 328°C. The optimized ceramic provides d 33 = 252 pC/N and g 33 = 20.9 × 10 −3 V m/N. A packaged sensor prototype achieves a maximum sensitivity of 75 dB at 108.7 kHz in pencil‐lead‐break tests. Results demonstrate that geometric optimization effectively enhances the performance of high‐ T c lead‐free AE sensors without altering measurement setups.
No takes yet. Share an insight, caveat, or question.
Koo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: