Why the study?
Does bipolar recording improve the reproducibility of ventricular fibrillation characteristics compared to unipolar recording in patients undergoing ICD implantation?
Does bipolar recording improve the reproducibility of ventricular fibrillation characteristics compared to unipolar recording in patients undergoing ICD implantation?
Bipolar electrogram recordings demonstrate better reproducibility than unipolar recordings during induced ventricular fibrillation, informing the design of VF detection algorithms.
Answers are grounded in this paper and cite their sources.
Bipolar recordings yield modestly higher VF reproducibility than unipolar; leaves open algorithm refinements pending prospective validation.
INTRODUCTION: The purpose of this study was to evaluate the immediate reproducibility of local electrogram characteristics recorded during repeated episodes of induced ventricular fibrillation (VF) in patients undergoing implantable cardioverter defibrillator (ICD) implantation. METHODS AND RESULTS: Power spectral analysis (using a fast Fourier transform algorithm) of electrograms recorded during 3 seconds of VF were analyzed in 24 patients undergoing ICD implantation using a Medtronic Transvene lead. Patients had 2 to 7 episodes of VF that were induced during defibrillation threshold testing. VF was induced by burst pacing (n = 20) or T wave shock (n = 4). Simultaneous electrograms during VF were recorded from a Medtronic Transvene lead with the following configurations: (1) a narrow spaced (12 mm) dedicated bipole used clinically for sensing; (2) a unipolar electrogram from the right ventricular coil; and (3) a widely spaced (18.3 mm) integrated bipole using the distal tip and the coil. Intraclass correlation coefficients (ICCs) were determined to examine the reproducibility of these VF characteristics among VF episodes in each patient. Recordings from both bipolar configurations had ICCs from 0.40 to 0.55, whereas unipolar recordings ICCs were below 0.40. Reproducibility was similar for dedicated and integrated recordings. CONCLUSIONS: Frequency characteristics of repeated episodes of VF induced in the same subjects show fair-to-good but not excellent reproducibility. Bipolar recordings were far more reproducible than unipolar recordings, but both bipolar configurations had similar reproducibility. These findings have implications for both the pathophysiology of induced VF and the design of VF detection algorithms.
No takes yet. Share an insight, caveat, or question.
Taneja et al. (1997) studied this question.