Key result
Transcranial Doppler detects microemboli in ~57% of patients 24 hours after TAVR.
Why the study?
Although intraprocedural microembolism during TAVR is well recognized, whether this embolic phenomenon continues in the postprocedural period was unknown.
What is the prevalence of neurovascular microemboli (HITS) 24 hours post-TAVR in patients undergoing unprotected TAVR?
Observational (n=51)
What is the prevalence of neurovascular microemboli (HITS) 24 hours post-TAVR in patients undergoing unprotected TAVR?
Answers are grounded in this paper and cite their sources.
A high prevalence of neurovascular microemboli (56.8%) persists 24 hours after TAVR, indicating that the embolic phenomenon continues into the postprocedural period.
Background: Neurolotic sequelae after transcatheter aortic valve replacement (TAVR) can cause significant morbidity and mortality. Transcranial Doppler (TCD) imaging can show real-time high intensity transient signals (HITS), which reflect active microembolization. Although it is well known that intraprocedural microembolism occurs, it is not known if this embolic phenomenon continues in the postprocedural period. We investigated whether microemboli occur post-TAVR and whether we could determine any clinical, procedural, or echocardiographic predictors. Methods: We evaluated HITS in 51 consecutive patients undergoing unprotected TAVR with low-, intermediate-, or high-risk Society of Thoracic Surgeons score. Patients were excluded if they did not have temporal windows for insonation of the middle cerebral artery or if they were not willing to participate. Primary outcomes of HITS 24 hours post-TAVR were observed using a Philips iU22 TCD. TCD was performed at 3 time points (pre-, peri-, and post-TAVR) for each patient, before, during, and 24 hours postprocedure. Results: While no HITS were detected in any of the patients preoperatively, all patients had HITS during the procedure. Interestingly, 56.8% had HITS 24 hours post-TAVR. One patient with HITS post-TAVR had a stroke 48 hours after TAVR. Conclusion: We observed a high prevalence of microemboli 24 hours post-TAVR. None of the predictors for intraprocedural microembolism seemed to play an important role for post-TAVR microemboli.
No takes yet. Share an insight, caveat, or question.
Sharma et al. (2023) conducted an observational in Transcatheter aortic valve replacement (TAVR) (n=51). Transcatheter aortic valve replacement (TAVR) was evaluated on High intensity transient signals (HITS) 24 hours post-TAVR. Transcranial Doppler imaging detected high intensity transient signals (microemboli) in 56.8% of patients 24 hours after transcatheter aortic valve replacement.
Synapse has enriched 10 related papers. Consider them for comparative context: