Key result
Cerebral protection devices during TAVR linked to ~32% fewer cerebral emboli vs no protection.
Why the study?
Periprocedural ischemic stroke remains a serious complication during TAVR, motivating the evaluation of a novel AI-equipped robotic transcranial Doppler system for safety, validity, and quantification of cerebral emboli with and without cerebral protection.
Does the use of cerebral protection devices reduce cerebral emboli detected by robotic transcranial Doppler in patients undergoing TAVR?
Observational (n=31)
Does the use of cerebral protection devices reduce cerebral emboli detected by robotic transcranial Doppler in patients undergoing TAVR?
Real-time intraoperative neuromonitoring with robotic transcranial Doppler demonstrated that cerebral protection devices significantly reduce cerebral emboli during TAVR, particularly during valve positioning and implantation.
Answers are grounded in this paper and cite their sources.
May reduce emboli during TAVR; hypothesis-generating and requires randomized confirmation before practice change.
Background Periprocedural ischemic stroke remains a serious complication in patients undergoing transcatheter aortic valve replacement (TAVR). We used a novel robotic transcranial Doppler (TCD) system equipped with artificial intelligence (AI) for real-time continuous intraoperative neuromonitoring during TAVR to establish the safety and potential validity of this tool in detecting cerebral emboli, report the quantity and distribution of high intensity transient signals (HITS) with and without cerebral protection, and correlate HITS occurrence with various procedural steps. Methods Consecutive patients undergoing TAVR procedures during which the robotic system was used between October 2021 and May 2022 were prospectively enrolled in this pilot study. The robotic TCD system included autonomous adjustment of the TCD probes and AI-assisted post-processing of HITS and other cerebral flow parameters. Basic demographics and procedural details were recorded. Continuous variables were analyzed by a two-sample Mann–Whitney t-test and categorical variables by a χ 2 or Fisher test. Results Thirty-one patients were prospectively enrolled (mean age 79.9±7.6 years; 16 men (51.6%)). Mean aortic valve stenotic area was 0.7 cm 2 and mean aortic–ventricular gradient was 43 mmHg (IQR 31.5–50 mmHg). Cerebral protection was used in 16 cases (51.6%). Significantly fewer emboli were observed in the protection group than in the non-protection group (mean 470.38 vs 693.33; p=0.01). Emboli counts during valve positioning and implantation were significantly different in the protection and non-protection groups (mean 249.92 and 387.5, respectively; p=0.01). One (4%) transient ischemic attack occurred post-procedurally in the non-protection group. Conclusion We describe a novel real-time intraoperative neuromonitoring tool used in patients undergoing TAVR. Significantly fewer HITS were detected with protection. Valve positioning–implantation was the most significant stage for intraprocedural HITS.
No takes yet. Share an insight, caveat, or question.
Baig et al. (2023) conducted an observational in Transcatheter aortic valve replacement (TAVR) (n=31). Cerebral protection devices vs. No cerebral protection was evaluated on Quantity of cerebral emboli (high intensity transient signals) (p=0.01). Cerebral protection devices used during TAVR were associated with significantly fewer cerebral emboli compared to no protection (mean 470.38 vs 693.33; p=0.01).