Why the study?
Recent studies characterized persistent AF drivers using panoramic basket catheter mapping, but whether repetitive atrial activation patterns could be identified via automated annotation of unipolar electrograms using high-density regional contact mapping remained to be determined.
Can high-density regional endocardial contact mapping identify repetitive atrial activation patterns in patients with persistent atrial fibrillation?
Can high-density regional endocardial contact mapping identify repetitive atrial activation patterns in patients with persistent atrial fibrillation?
Answers are grounded in this paper and cite their sources.
High-resolution endocardial mapping can identify repetitive atrial activation patterns in persistent AF, revealing that focal firing is the most frequently observed pattern.
Introduction Recent studies have characterized drivers in persistent atrial fibrillation using automated algorithm detection with panoramic endocardial mapping by means of basket catheters. We aimed to identify repetitive atrial activation patterns (RAAPs) during ongoing atrial fibrillation (AF) based upon automated annotation of unipolar electrograms (EGMs) recorded with a high‐density regional endocardial contact mapping catheter. Methods In 14 persistent AF patients, high‐resolution EGMs were recorded for 30 seconds at sequential PentaRay (Biosense Inc) positions covering the entire biatrial surface. All recordings were reviewed off‐line with dedicated software allowing automated annotation of the local activation time of the unipolar fibrillatory EGMs (CARTOFINDER; Biosense Inc). RAAPs were defined as a consistent activation pattern (for ≥3 consecutive beats) of either focal activity with centrifugal spread (RAAP focal ) or rotational activity across the PentaRay splines spanning the AF cycle length (RAAP rotational ). Results A total of 498 PentaRay recordings were analyzed (35.6 ± 7.6 per patient). The number of PentaRay recordings displaying RAAP was 9.8 ± 3.1 per patient (range = 3‐15), of which 2.4 ± 2.4 RAAP rotational (range = 0‐7), and 7.4 ± 4.4 RAAP focal (range = 1‐13). 77% of RAAPs portrayed focal firing. The median number of repetitions per 30 second recording was 11 (range = 3‐225) per recording. RAAPs were observed both in the right atrium (RA) (35%) and left atrium (LA) (65%), with the majority being near the left PVs/appendage (35% of all RAAPs) and the superior vena cava/right appendage (23% of all RAAPs). Conclusion High‐resolution, sequential endocardial EGM‐based mapping allows identification of RAAPs in persistent AF. In our series, focal firing was the most frequently observed pattern.
No takes yet. Share an insight, caveat, or question.
Wolf et al. (2019) studied this question.