Why the study?
Does high-sensitivity cardiac troponin I testing with sex-specific cutoffs increase the diagnosis of acute myocardial infarction in women compared to contemporary troponin I testing?
Does high-sensitivity cardiac troponin I testing with sex-specific cutoffs increase the diagnosis of acute myocardial infarction in women compared to contemporary troponin I testing?
Adopting sex-specific cutoffs for hs-cTnI increases the proportion of women with elevated troponin but does not lead to a corresponding increase in AMI diagnoses or angiography rates.
No rise in AMI diagnoses despite more women exceeding hs-cTnI thresholds; leaves open whether sex-specific cutoffs improve outcomes.
BACKGROUND: High-sensitivity cardiac troponin I (hs-cTnI) assays show sex-dependent differences in the 99th percentile of healthy populations, with concentrations in women approximately 50% lower. The adoption of sex-specific cutoffs seems appropriate, although it is not yet clear what effect these will have on acute myocardial infarction (AMI) diagnosis and management. METHODS: We conducted a retrospective pre- and postchangeover analysis of troponin I testing in the 6 months before and after moving from the contemporary Abbott Architect TnI assay (cTnI) to hs-cTnI at 2 tertiary centers in Australia and New Zealand. The cTnI cutoff was 30 ng/L for both sexes, whereas a female-specific cutoff of 16 ng/L was adopted upon changeover to hsTnI. RESULTS: Changeover from the cTnI assay to the hs-cTnI assay increased the number of female patients with increased troponin I concentrations at both sites (from 29.7% to 34.9% and from 22.4% to 30.8%; P < 0.001). There was no statistically significant change in the number of men with increased concentrations in the same time period (P = 0.09). The increased percentage of women with increased troponin I was not associated with an increase in the number of women with AMI diagnoses at either center. Angiographic data available from 1 center showed no change in the percentage of angiograms performed in women. CONCLUSIONS: Although increasing the proportion of women with increased troponin I, adopting sex-specific cutoffs with the hs-cTnI assay did not lead to an increase in AMI diagnoses in females, or in the number of women undergoing angiography.
No takes yet. Share an insight, caveat, or question.
Trambas et al. (2016) studied this question.