Why the study?
Does electrical cardioversion reverse atrial electrical remodeling and do post-conversion electrical properties predict recurrence in patients with chronic atrial fibrillation?
Does electrical cardioversion reverse atrial electrical remodeling and do post-conversion electrical properties predict recurrence in patients with chronic atrial fibrillation?
Atrial electrical remodeling (ERP and repolarization shortening) reverses within 24 hours after cardioversion of chronic AF, and immediate post-conversion MAPd90 values predict AF recurrence.
Answers are grounded in this paper and cite their sources.
Immediate post-cardioversion MAPd90 may stratify AF relapse risk; hypothesis-generating for remodeling-targeted strategies in chronic AF.
OBJECTIVE: To study the reversibility of atrial electrical remodeling and its relation with recurrence in post-conversion chronic atrial fibrillation (CAF) patients. METHODS: In 28 drug-free CAF patients (mean AF duration 41+/-39 months) electrically converted to sinus rhythm effective refractory period (ERP) at 500 ms, monophasic action potential at 90% of repolarization (MAPd90) at five cycle lengths (CL, 350, 400, 450, 500, 600 ms), and P wave duration were measured three times: within the interval 5-20 min post-conversion, 24 h and 1 month later. Fifteen subjects with no history of AF and normal atrial structure served as a control group. Patients were followed up for recurrence for 1 month; 12 relapsed. RESULTS: ERP changed from 205+/-20 to 243+/-31 to 241+/-24 ms (P<0. 001), attaining a level comparable to that of the controls (238+/-21 ms) within 24 h. MAPd90 significantly (P<0.001) increased (from 175+/-11 to 190+/-19 to 191+/-10 ms at CL 350 ms and 201+/-12 to 234+/-20 and 233+/-23 ms at CL 600 ms) also reaching control levels within 24 h. MAPd90 exhibited an abnormal adaptation to rate only in the first evaluation. P wave duration was prolonged (137+/-33 ms) and exhibited a slower course of shortening (130+/-32 to 123+/-27 ms, P<0.001), reaching control levels within 1 month. Patients with higher values of MAPd90 at CL 350 in the immediate post-conversion period were more likely to relapse (P<0.005). CONCLUSIONS: ERP and repolarization shortening as a result of CAF are reversed within 24 h after conversion, while P wave duration reduces more slowly. Post-conversion MAPd90 values contain prognostic information for recurrence.
No takes yet. Share an insight, caveat, or question.
E. G. Manios (2000) studied this question.