Why the study?
Does short AV delay reduce cardiac output in AV blocked canine preparations during AV sequential pacing?
Does short AV delay reduce cardiac output in AV blocked canine preparations during AV sequential pacing?
Short AV delay during AV sequential pacing decreases cardiac output by interrupting late diastolic atrial transport in a canine model.
Answers are grounded in this paper and cite their sources.
Short AV delay may reduce CO in paced canines; leaves open relevance to human AV optimization.
Short atrioventricular (AV) delay modifies late diastolic filling dynamics. The effect of this change on cardiac output (CO) was studied in closed chest, AV blocked canine preparations (N:10), during AV sequential pacing (80 bpm). CO (thermodilution technique) and transmitral flow velocity (TMFV, pulsed-wave Doppler) were measured and compared (paired t-test) on the basis of TMFV pattern, when atrial contraction (A wave) started just after early diastolic transmitral flow deceleration (PR: 219 +/- 25 ms, mean +/- SD) and when A wave occurred at the end of late diastole and shortened due to the next ventricular contraction (PR: 56 +/- 11 ms). The short AV delay resulted in 12.0 +/- 5.9% decrease of CO, reflecting the interrupted late diastolic atrial transport. Properly timed atrial contraction is necessary for optimal AV sequential pacing.
No takes yet. Share an insight, caveat, or question.
Rónaszéki et al. (1990) studied this question.