Why the study?
FFR demonstrated discrepancy between angiographic and functional significance of jailed side branches and moderate in-stent restenosis, prompting an evaluation of FFR utility and comparison with SPECT-MPI.
How does fractional flow reserve correlate with SPECT-MPI in assessing coronary artery lesions in patients with stable ischemic coronary artery disease?
How does fractional flow reserve correlate with SPECT-MPI in assessing coronary artery lesions in patients with stable ischemic coronary artery disease?
FFR correlates significantly with SPECT-MPI summed difference score in assessing coronary lesions, with similar diagnostic accuracy at FFR cutoffs of 0.75 and 0.80.
Background: Functional flow reserve (FFR) is used to determine functional significance of coronary artery stenosis. FFR demonstrated discrepancy between angiographic and functional significance of jailed side branches (JSBs) as well as moderate in-stent restenosis (ISR), with only minority of such lesions having functional significance. An attempt was made to study the utility of FFR and comparison of FFR with single-photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI) in native coronary artery stenoses.Methods: A total of 101 lesions in 79 patients with stable ischemic coronary artery disease were subjected to FFR and SPECT-MPI including native as well as ISR and JSB. Relation between FFR and perfusion imaging was analyzed quantitatively. Sensitivity, specificity, positive predictive value, and negative predictive value were used for diagnostic accuracy.Results: FFR was ≤≤ 0.75 in majority of the lesions having >70% stenosis. Most of the lesions having reversible perfusion defect had FFR ≤≤ 0.80. There was a significant negative correlation between summed difference score (SPECT-MPI) with FFR value. As FFR value decreased, summed difference score increased. Sensitivity and specificity did not differ much when FFR cutoff was taken as 0.75 or 0.80.Conclusion: There was a significant negative correlation between FFR and sum difference score (SPECT-MPI). Sensitivity and specificity of SPECT-MPI did not differ much when FFR value cutoff was taken as 0.75 or 0.80.
No takes yet. Share an insight, caveat, or question.
Phalgune et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: