Why the study?
To evaluate the association of longitudinal changes in physical activity with long-term outcomes after ICD or CRT-D implantation.
Does improved physical activity reduce cardiac death and all-cause mortality in patients with ICD or CRT-D implantation?
Does improved physical activity reduce cardiac death and all-cause mortality in patients with ICD or CRT-D implantation?
Improved physical activity over 12 months post-ICD/CRT-D implantation is associated with significantly reduced risks of cardiac death and all-cause mortality.
Increased activity associated with lower mortality post-device; leaves open whether interventions improve outcomes in randomized trials.
OBJECTIVE: To evaluate the association of longitudinal changes in physical activity (PA) with long-term outcomes after implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) implantation. METHODS: Patients with ICD/CRT-D implantation from SUMMIT registry were retrospectively analyzed. Accelerometer-derived PA changes over 12 months post implantation were obtained from the archived home monitoring data. The primary endpoints were cardiac death and all-cause mortality. The secondary endpoints were the first ventricular arrthymia (VA) and first appropriate ICD shock. RESULTS: In 705 patients, 446 (63.3%) patients showed improved PA over 12 months after implantation. During a mean 61.5-month follow-up duration, 99 cardiac deaths (14.0%) and 153 all-cause deaths (21.7%) occurred. Compared to reduced/unchanged PA, improved PA over 12 months could result in significantly reduced risks of cardiac death (improved PA ≤ 30 min: hazard ratio (HR) = 0.494, 95% CI: 0.288-0.848; > 30 min: HR = 0.390, 95% CI: 0.235-0.648) and all-cause mortality (improved PA ≤ 30 min: HR = 0.467, 95%CI: 0.299-0.728; > 30 min: HR = 0.451, 95% CI: 0.304-0.669). No differences in the VAs or ICD shocks were observed across different groups of PA changes. PA changes can predict the risks of cardiac death only in the low baseline PA group, but improved PA was associated with 56.7%, 57.4%, and 62.3% reduced risks of all-cause mortality in the low, moderate, and high baseline PA groups, respectively, than reduced/unchanged PA. CONCLUSIONS: Improved PA could protect aganist cardiac death and all-cause mortality, probably reflecting better clinical efficacy after ICD/CRT-D implantation. Low-intensity exercise training might be encouraged among patients with different baseline PA levels.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: