The described computer graphical technique enables 3D reconstruction of the human left ventricle from biplane cineangiograms, facilitating finite element stress analysis and volume calculations.
Answers are grounded in this paper and cite their sources.
Supports computational LV modeling from angiograms; leaves open integration into routine clinical decision-making.
A computer graphical technique is described for reconstructing the three-dimensional geometry of the human left ventricle of the heart from biplane cineangiograms. The views used are right and left anterior oblique. The reconstructed shape is intended for three-dimensional mesh generation for finite element stress analysis, but may also be useful for clinical diagnostic purposes and for cavity volume calculation throughout the cardiac cycle.
No takes yet. Share an insight, caveat, or question.
Yettram et al. (1982) studied this question.