Why the study?
Does ultrasound analysis of carotid plaque gray-scale median (GSM) predict cerebro-cardiovascular events in patients with type 2 diabetes?
Does ultrasound analysis of carotid plaque gray-scale median (GSM) predict cerebro-cardiovascular events in patients with type 2 diabetes?
Ultrasound-derived carotid plaque gray-scale median (GSM) <32 is a significant predictor of cerebro-cardiovascular events in patients with type 2 diabetes.
May support GSM for risk stratification in type 2 diabetes; hypothesis-generating and requires prospective validation before clinical adoption.
AIMS/INTRODUCTION: Measurements of plaque echogenicity, the gray-scale median (GSM), were shown to correlate inversely with risk factors for cerebro-cardiovascular disease (CVD). The eicosapentaenoic acid (EPA)/arachidonic acid (AA) ratio is a potential predictor of CVD risk. In the present study, we assessed the usefulness of carotid plaque GSM values and EPA/AA ratios in atherosclerotic diabetics. MATERIALS AND METHODS: A total of 84 type 2 diabetics with carotid artery plaques were enrolled. On admission, platelet aggregation and lipid profiles, including EPA and AA, were examined. Using ultrasound, mean intima media thickness and plaque score were measured in carotid arteries. Plaque echogenicity was evaluated using computer-assisted quantification of GSM. The patients were then further observed for approximately 3 years. RESULTS: Gray-scale median was found to be a good marker of CVD events. On multivariate logistic regression analysis, GSM <32 and plaque score ≥5 were significantly associated with past history and onset of CVD during the follow-up period, the odds ratios being 7.730 (P = 0.014) and 4.601 (P = 0.046), respectively. EPA/AA showed a significant correlation with GSM (P = 0.012) and high-density lipoprotein cholesterol (P = 0.039), and an inverse correlation with platelet aggregation (P = 0.046) and triglyceride (P = 0.020). Although most patients with CVD had both low GSM and low EPA/AA values, an association of EPA/AA with CVD events could not be statistically confirmed. CONCLUSIONS: The present results suggest the GSM value to be useful as a reference index for CVD events in high-risk atherosclerotic diabetics. Associations of the EPA/AA ratio with known CVD risk factors warrant a larger and more extensive study to show the usefulness of this parameter.
No takes yet. Share an insight, caveat, or question.
Ariyoshi et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: