Key result
Equilibrium radionuclide angiography strongly predicted acute response to CRT, with an LV phase standard deviation cut-off of 8.5% yielding 87% sensitivity and 89% specificity (AUC=0.95).
Why the study?
Does equilibrium radionuclide angiography (ERNA) predict acute response to cardiac resynchronization therapy in patients with heart failure?
Observational (n=24)
Does equilibrium radionuclide angiography (ERNA) predict acute response to cardiac resynchronization therapy in patients with heart failure?
Equilibrium radionuclide angiography (ERNA) parameters, specifically left ventricular phase shift and standard deviation, can accurately predict acute volumetric response to cardiac resynchronization therapy.
ERNA phase SD may aid acute CRT response prediction; leaves open prospective validation before clinical use.
OBJECTIVE: To predict the acute response to cardiac resynchronization therapy (CRT) in patients with left ventricular mechanical dyssynchrony using equilibrium radionuclide angiography (ERNA). PATIENTS AND METHODS: A total of 24 consecutive heart failure patients scheduled for CRT were included. ERNA was performed before and within 48 h after pacemaker implantation to calculate both left ventricular (LV) volumes and LV dyssynchrony. LV dyssynchrony was defined as the standard left ventricular phase shift and left ventricular phase standard deviation (LVPS% and LVPSD%). Patients were subsequently divided into acute responders or nonresponders, based on a reduction of at least 15% in LV end-systolic volume immediately after CRT. RESULTS: Fifteen patients (63%) were classified as acute responders. Baseline characteristics were similar between responders and nonresponders except for the LVPS% and LVPSD%, which were larger in responders. Moreover, responders demonstrated a significant reduction of LVPS% and LVPSD% immediately after CRT (from 28.00±2.88 to 17.53±4.94 and 11.20±2.54 to 5.60±1.80, P<0.001), whereas in nonresponders LVPS% and LVPSD% remained unchanged (from 21.44±3.91 to 19.56±4.22% and 6.55±1.51 to 6.22±1.30%, P=NS). Receiver operating characteristic curve analysis revealed that a cut-off value of 25% for LVPS%, a sensitivity of 80% with a specificity of 89% were obtained to predict acute ERNA response to CRT (area under the curve=0.93) and a cut-off value of 8.5% for LVPSD%, a sensitivity of 87% with a specificity of 89% were obtained to predict acute ERNA response to CRT (area under the curve=0.95). CONCLUSION: ERNA is highly predictive for acute response to CRT. ERNA also allows assessment of changes in LV volumes and LV ejection fraction before and after CRT implantation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2015) conducted an observational in Heart failure (n=24). Equilibrium radionuclide angiography (ERNA) was evaluated on Acute response to CRT (≥15% reduction in LV end-systolic volume) (AUC 0.95 for LVPSD%). Equilibrium radionuclide angiography strongly predicted acute response to CRT, with an LV phase standard deviation cut-off of 8.5% yielding 87% sensitivity and 89% specificity (AUC=0.95).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: