Key result
The detailed method of endocardium tracing, which includes papillary muscles in the ventricular mass, resulted in an 11% higher ejection fraction measurement in normal pig hearts and 19% higher in infarcted hearts compared to the standard method.
Why the study?
CMRI accuracy for left ventricular volume and contractility decreases with abnormally enlarged papillary muscles, prompting a study to establish the best method of LVV quantification in pigs.
Does the detailed method of CMRI contouring improve the accuracy of LV mass and ejection fraction measurements compared to the standard method in Yucatan minipigs?
Does the detailed method of CMRI contouring improve the accuracy of LV mass and ejection fraction measurements compared to the standard method in Yucatan minipigs?
In Yucatan minipig models, including papillary muscles and trabeculations in the LV mass during CMRI analysis significantly improves the accuracy of LV mass and ejection fraction measurements.
Answers are grounded in this paper and cite their sources.
May bias EF estimates in porcine models; extends papillary inclusion effects to infarcted hearts but leaves open human translation.
(1) Background: The accuracy of the left ventricular volume (LVV) and contractility measurements with cardiac magnetic resonance imaging (CMRI) is decreased if the papillary muscles are abnormally enlarged, such as in hypertrophic cardiomyopathy in human patients or in pig models of human diseases. The purpose of this work was to establish the best method of LVV quantification with CMRI in pigs. (2) Methods: The LVV in 29 Yucatan minipig hearts was measured using two different techniques: the “standard method”, which uses smooth contouring along the endocardial surface and adds the papillary volume to the ventricular cavity volume, and the “detailed method”, which traces the papillary muscles and trabeculations and adds them to the ventricular mass. (3) Results: Papillary muscles add 21% to the LV mass in normal and infarcted hearts of Yucatan minipigs. The inclusion or exclusion of these from the CMRI analysis significantly affected the study results. In the normal pig hearts, the biggest differences were found in measurements of the LVV, ejection fraction (EF), LV mass and indices derived from the LV mass (p < 0.001). The EF measurement in the normal pig heart was 11% higher with the detailed method, and 19% higher in the infarcted pig hearts (p < 0.0001). The detailed method of endocardium tracing with CMRI closely represented the LV mass measured ex vivo. (4) Conclusions: The detailed method, which accounts for the large volume of the papillary muscles in the pig heart, provides better accuracy and interobserver consistency in the assessment of LV mass and ejection fraction, and might therefore be preferable for these analyses.
No takes yet. Share an insight, caveat, or question.
Naumova et al. (2021) studied Normal and infarcted hearts (n=29). Detailed method of endocardium tracing vs. Standard method of smooth contouring was evaluated on Ejection fraction measurement in normal pig hearts (p=<0.0001). The detailed method of endocardium tracing, which includes papillary muscles in the ventricular mass, resulted in an 11% higher ejection fraction measurement in normal pig hearts and 19% higher in infarcted hearts compared to the standard method.
Synapse has enriched 10 related papers. Consider them for comparative context: