Key result
An ANN-based reduced order model accurately reproduced high fidelity cardiac electromechanical models with an error order of 10−3 and a computational speedup of about one order of magnitude.
Why the study?
High fidelity mathematical models of active force generation in cardiac muscle feature high computational burdens due to large numbers of state variables.
A machine learning-based reduced order model can efficiently and accurately simulate cardiac electromechanics, significantly reducing computational burden.
Answers are grounded in this paper and cite their sources.
May accelerate research simulations of cardiac electromechanics; leaves open clinical translation pending validation.
High fidelity (HF) mathematical models describing the generation of active force in the cardiac muscle tissue typically feature a large number of state variables to capture the intrinsically complex underlying subcellular mechanisms. With the aim of drastically reducing the computational burden associated with the numerical solution of these models, we propose a machine learning method that builds a reduced order model (ROM); this is obtained as the best-approximation of the HF model within a class of candidate differential equations based on Artificial Neural Networks (ANNs). Within a semiphysical (gray-box) approach, an ANN learns the dynamics of the HF model from input–output pairs generated by the HF model itself (i.e. non-intrusively), being additionally informed with some a priori knowledge about the HF model. The ANN-based ROM, with just two internal variables, can accurately reproduce the results of the HF model, that instead features more than 2000 variables, under several physiological and pathological working regimes of the cell. We then propose a multiscale 3D cardiac electromechanical model, wherein active force generation is described by means of the previously trained ANN. We achieve a very favorable balance between accuracy of the result (order of 10−3 for the main cardiac biomarkers) and computational efficiency (with a speedup of about one order of magnitude), still relying on a biophysically detailed description of the microscopic force generation phenomenon.
No takes yet. Share an insight, caveat, or question.
Regazzoni et al. (2020) studied Cardiac electromechanics (computational modeling). Artificial Neural Network (ANN)-based reduced order model (ROM) vs. High fidelity (HF) mathematical model was evaluated on Accuracy and computational efficiency. An ANN-based reduced order model accurately reproduced high fidelity cardiac electromechanical models with an error order of 10−3 and a computational speedup of about one order of magnitude.
Synapse has enriched 10 related papers. Consider them for comparative context: