Key result
The CT-derived Agatston score was the only independent predictor of more than mild paravalvular leakage after TAVI with a CoreValve prosthesis, regardless of the imaging technique used.
Why the study?
Do CT-derived variables predict significant paravalvular leakage after TAVI with a CoreValve system?
Observational (n=164)
No
Do CT-derived variables predict significant paravalvular leakage after TAVI with a CoreValve system?
Answers are grounded in this paper and cite their sources.
The CT-derived Agatston score is an independent predictor of paravalvular leakage after TAVI with a CoreValve prosthesis, regardless of the imaging technique used for PVL definition.
Significant paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) is related to patient mortality. Predicting the development of PVL has focused on computed tomography (CT) derived variables but literature targeting CoreValve devices is limited, controversial, and did not make use of standardized echocardiographic methods. The study included 164 consecutive patients with severe aortic stenosis that underwent TAVI with a Medtronic CoreValve system©, with available pre-TAVI CT and pre-discharge transthoracic echocardiography. The predictive value for significant PVL of the CT-derived Agatston score, aortic annulus size and eccentricity, and "cover index" was assessed, according to both echocardiographic Valve Academic Research Consortium (VARC) criteria and angiographic Sellers criteria. Univariate predictors for more than mild PVL were the maximal diameter of the aortic annulus size (for both angiographic and echocardiographic assessment of PVL), cover index (for echocardiographic assessment of PVL only), and Agatston score (for both angiographic and echocardiographic assessment of PVL). The aortic annulus eccentricity index was not predicting PVL. At multivariate analysis, Agatston score was the only independent predictor for both angiographic and echocardiographic assessment of PVL. Agatston score is the only independent predictor of PVL regardless of the used imaging technique for the definition of PVL.
No takes yet. Share an insight, caveat, or question.
Martino et al. (2015) conducted an observational in Severe aortic stenosis (n=164). Transcatheter aortic valve implantation (TAVI) with Medtronic CoreValve was evaluated on Independent predictors of more than mild paravalvular leakage (PVL) assessed by echocardiography (VARC-2) (β 0.265, p=0.001). The CT-derived Agatston score was the only independent predictor of more than mild paravalvular leakage after TAVI with a CoreValve prosthesis, regardless of the imaging technique used.