Key result
A deep learning framework with quality control assessment achieved a coefficient of determination (R2) of 0.968 for left atrial volume estimation from cardiac CT images compared to manual segmentation.
Why the study?
Pre-operative cardiac CT allows full volumetric left atrium measurement for recurrence risk stratification before catheter ablation for AF, but fully automated computation with quality control is needed.
Does a deep learning framework accurately and automatically estimate left atrial volume from cardiac CT images in patients with atrial fibrillation?
Observational (n=337)
No
Does a deep learning framework accurately and automatically estimate left atrial volume from cardiac CT images in patients with atrial fibrillation?
Effect estimate: R2 0.968
A fully automated deep learning framework can accurately estimate left atrial volume from cardiac CT images with built-in quality control, enabling high-throughput reproducible measurements for clinical and research use.
May enable scalable LAV assessment in AF cohorts; leaves open prospective validation before clinical adoption.
OBJECTIVES: Cardiac computed tomography (CCT) is a common pre-operative imaging modality to evaluate pulmonary vein anatomy and left atrial appendage thrombus in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). These images also allow for full volumetric left atrium (LA) measurement for recurrence risk stratification, as larger LA volume (LAV) is associated with higher recurrence rates. Our objective is to apply deep learning (DL) techniques to fully automate the computation of LAV and assess the quality of the computed LAV values. METHODS: Using a dataset of 85,477 CCT images from 337 patients, we proposed a framework that consists of several processes that perform a combination of tasks including the selection of images with LA from all other images using a ResNet50 classification model, the segmentation of images with LA using a UNet image segmentation model, the assessment of the quality of the image segmentation task, the estimation of LAV, and quality control (QC) assessment. RESULTS: (the coefficient of determination) value of 0.968 in the volume estimation task. It correctly identified 9 out of 10 poor LAV estimations from a total of 337 patients as poor-quality estimates. CONCLUSIONS: We proposed a generalizable framework that consists of DL models and computational methods for LAV estimation. The framework provides an efficient and robust strategy for QC assessment of the accuracy for DL-based image segmentation and volume estimation tasks, allowing high-throughput extraction of reproducible LAV measurements to be possible.
No takes yet. Share an insight, caveat, or question.
Abdulkareem et al. (2022) conducted an observational in Symptomatic, anti-arrhythmic medication-refractory atrial fibrillation (n=337). Deep learning framework for left atrial volume estimation vs. Manual segmentation was evaluated on Coefficient of determination (R2) for volume estimation (R2 0.968). A deep learning framework with quality control assessment achieved a coefficient of determination (R2) of 0.968 for left atrial volume estimation from cardiac CT images compared to manual segmentation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: