Key result
Patients with resistant hypertension had significantly greater torsion hysteresis area compared to healthy controls, indicating stiffer ventricles and impaired left ventricular suction.
Why the study?
Does torsion hysteresis area measured by CMR differ between patients with resistant hypertension and normal controls?
Cross-Sectional (n=100)
No
Does torsion hysteresis area measured by CMR differ between patients with resistant hypertension and normal controls?
Torsion hysteresis area derived from normalized torsion shear angle-volume loops provides a novel global index of left ventricular diastolic function that is significantly altered in patients with resistant hypertension.
Answers are grounded in this paper and cite their sources.
Torsion hysteresis may identify diastolic dysfunction in resistant hypertension; hypothesis-generating and requires prospective validation before clinical adoption.
BACKGROUND: Torsion shear angle φ is an important measure of left ventricular (LV) systolic and diastolic functions. Here we provide a novel index utilizing LV normalized torsion shear angle φ ^ volume V ^ loop to assess LV diastolic functional properties. We defined the area within φ ^ V ^ loop as torsion hysteresis area, and hypothesized that it may be an important global parameter of diastolic function. We evaluated the φ ^ changes to increased V ^ during early diastole - d φ ^ / d V ^ as a potential measure of LV suction. METHODS: Sixty resistant hypertension patients (HTN), forty control volunteers were studied using cardiovascular magnetic resonance with tissue tagging. Volumetric and torsional parameters were evaluated. RESULTS: HTN demonstrated concentric remodeling with preserved ejection fraction. HTN had significantly decreased normalized early filling rate, early diastolic mitral annulus velocity and E/A (1.33 ± 1.13 vs. 2.19 ± 1.07, P < 0.0001) vs. control. Torsion hysteresis area was greater (0.11 ± 0.07 vs. 0.079 ± 0.045, P < 0.001) and peak - d φ ^ / d V ^ at early diastole was higher (10.46 ± 8.51 vs. 6.29 ± 3.85, P = 0.002) than control. Torsion hysteresis area was significantly correlated with E/A (r = -0.23, P = 0.025). Thirteen HTN patients had both E/A ratio < 1.12 (Control mean E/A-1SD) and torsion hysteresis area > 0.12 (Control mean torsion hysteresis area + 1SD). CONCLUSIONS: Torsion hysteresis area and peak early diastolic - d φ ^ / d V ^ were significantly increased in hypertensive concentric remodeling. The φ ^ V ^ loop takes into account the active and passive recoil processes of LV diastolic and systolic phases, therefore provides a new global description of LV diastolic function.
No takes yet. Share an insight, caveat, or question.
Schiros et al. (2014) conducted a cross-sectional in Resistant hypertension (n=100). Cardiovascular magnetic resonance with tissue tagging vs. Healthy controls was evaluated on Torsion hysteresis area (p=<0.001). Patients with resistant hypertension had significantly greater torsion hysteresis area compared to healthy controls, indicating stiffer ventricles and impaired left ventricular suction.
Synapse has enriched 10 related papers. Consider them for comparative context: