Key result
Piezoelectric sensor detects significantly higher systolic murmur amplitudes in neonates with congenital heart defects.
Why the study?
The study aimed to evaluate the capability of a piezoelectric sensor to detect heart murmurs in patients with congenital heart defects.
Does a piezoelectric sensor accurately detect pathologic systolic heart murmurs in neonates with congenital heart defects compared to an electronic stethoscope?
Cross-Sectional (n=18)
No
Does a piezoelectric sensor accurately detect pathologic systolic heart murmurs in neonates with congenital heart defects compared to an electronic stethoscope?
p-value: p=<0.01
A piezoelectric sensor can noninvasively and objectively detect pathologic systolic heart murmurs in neonates with congenital heart defects, offering a potential screening tool that minimizes handling.
Supports piezoelectric sensors for objective neonatal murmur assessment; hypothesis-generating for CHD screening, requiring prospective validation before adoption.
This study aimed to evaluate the capability of a piezoelectric sensor to detect a heart murmur in patients with congenital heart defects. Heart sounds and murmurs were recorded using a piezoelectric sensor and an electronic stethoscope in healthy neonates (n = 9) and in neonates with systolic murmurs caused by congenital heart defects (n = 9) who were born at a hospital. Signal data were digitally filtered by high-pass filtering, and the envelope of the processed signals was calculated. The amplitudes of systolic murmurs were evaluated using the signal-to-noise ratio and compared between healthy neonates and those with congenital heart defects. In addition, the correlation between the amplitudes of systolic murmurs recorded by the piezoelectric sensor and electronic stethoscope was determined. The amplitudes of systolic murmurs detected by the piezoelectric sensor were significantly higher in neonates with congenital heart defects than in healthy neonates (p < 0.01). Systolic murmurs recorded by the piezoelectric sensor had a strong correlation with those recorded by the electronic stethoscope (ρ = 0.899 and p < 0.01, respectively). The piezoelectric sensor can detect heart murmurs objectively. Mechanical improvement and automatic analysis algorithms are expected to improve recording in the future.
No takes yet. Share an insight, caveat, or question.
Takahashi et al. (2021) conducted a cross-sectional in Congenital heart defects (n=18). Piezoelectric sensor vs. Healthy neonates was evaluated on Signal-to-noise ratio (SNRsys) of systolic murmurs (p=<0.01). The piezoelectric sensor detected significantly higher amplitudes of systolic murmurs in neonates with congenital heart defects compared to healthy neonates (p < 0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: