Key result
Measurement of 3D vena contracta area by TEE was superior to 2D PISA for determining severe regurgitation, showing 88% agreement with the integrative method compared to 65% for 2D PISA.
Why the study?
Does 3D vena contracta area quantitation by TEE improve the accuracy of grading valvular regurgitation severity compared to the 2D PISA method?
Observational (n=116)
Does 3D vena contracta area quantitation by TEE improve the accuracy of grading valvular regurgitation severity compared to the 2D PISA method?
Absolute Event Rate: 88% vs 65%
3D vena contracta area by TEE is more feasible and accurate than the 2D PISA method for grading valvular regurgitation severity, particularly in cases with multiple jets or severe regurgitation.
Supports 3D VCA by TEE for severe regurgitation grading; leaves open prospective validation before practice change.
BACKGROUND: Quantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three-dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE). METHODS: We evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE-recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade. RESULTS: Mean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively. CONCLUSION: Measurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves.
No takes yet. Share an insight, caveat, or question.
Abudiab et al. (2017) conducted an observational in Valvular regurgitation (n=116). 3D vena contracta area (VCA) by TEE vs. 2D proximal isovelocity acceleration (PISA) method was evaluated on Agreement with the integrative method for severe regurgitation. Measurement of 3D vena contracta area by TEE was superior to 2D PISA for determining severe regurgitation, showing 88% agreement with the integrative method compared to 65% for 2D PISA.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: