Key result
3D TTE LVOT area yields optimal continuity-equation AVA agreement with 3D planimetry across valve morphologies.
Why the study?
Proposed solutions for LVOT diameter underestimation in aortic valve area calculation by the continuity equation relied on 2D imaging and were validated exclusively in tricuspid aortic valves. Evidence to guide LVOT assessment using 3D transthoracic echocardiography in bicuspid valves was lacking despite recognized differences in LVOT morphology.
Does 3D transthoracic echocardiography assessment of the left ventricular outflow tract improve the accuracy of aortic valve area calculation by the continuity equation compared to 3D planimetry in patients with tricuspid and bicuspid aortic valves?
Observational (n=200)
Does 3D transthoracic echocardiography assessment of the left ventricular outflow tract improve the accuracy of aortic valve area calculation by the continuity equation compared to 3D planimetry in patients with tricuspid and bicuspid aortic valves?
Answers are grounded in this paper and cite their sources.
3D TTE-derived LVOT area provides the most accurate continuity equation aortic valve area calculations for both tricuspid and bicuspid aortic valves, whereas 2D LVOT diameter underestimates aortic valve area (with less error when measured at the annulus).
Purpose The weakest link in aortic valve area (AVA) calculation by the continuity equation (AVA CE) during 2D transthoracic echocardiography (TTE) is underestimation of the left ventricular outflow tract (LVOT) diameter (LVOTD). Proposed solutions were founded on 2D imaging, geometrical assumptions, and validated exclusively in tricuspid aortic valves (TAV). There is little evidence to guide imaging optimization in bicuspid valves (BAV) despite recognized differences in their LVOT morphologies. We aimed to determine the optimal approach for LVOT assessment in TAVs and BAVs using 3D TTE. Methods Patients with 2D and 3D TTE assessments of the LVOT and aortic valve were identified. LVOTDs were measured on 2D images while multiplanar reconstructions of the 3D datasets were performed to obtain LVOT area (LVOTA) and circumference (LVOTC). AVA CE was calculated using the different 2D/3D LVOT measurements and compared with AVA by 3D planimetry (AVA 3D). Results 100 TAVs (mean age 46.2 ± 17.5years, 36% females) and 100 BAVs (34.9 ± 14.5years, 50% females) were included. In comparison to AVA 3D, calculation of AVA CE in TAVs was best using 3D LVOTA (Intraclass correlation coefficient (ICC)>0.9; P < 0.001), while LVOTC resulted in overestimation of the AVA due to greater LVOT ellipticity. In BAVs, both 3D LVOTA and LVOTC resulted in ICCs>0.9 (P < 0.001). 2D LVOTDs resulted in underestimation of the AVA with a smaller error if measured at the annulus. Conclusions 3D TTE provides optimal assessments of the LVOT for AVA CE calculations. 3D‐based LVOTAs are suitable for both TAVs and BAVs. If 3D is unavailable, 2D LVOTD measurements should be performed at the annulus.
No takes yet. Share an insight, caveat, or question.
Frampton et al. (2026) conducted an observational in Tricuspid and bicuspid aortic valves undergoing aortic valve area assessment (n=200). 3D transthoracic echocardiography left ventricular outflow tract area (LVOTA) and circumference (LVOTC) assessment vs. 2D LVOT diameter assessment and 3D planimetry (AVA 3D) was evaluated on Agreement of continuity equation aortic valve area (AVA CE) with 3D planimetry (AVA 3D) (ICC >0.9, p=<0.001). 3D TTE LVOT area provided optimal agreement with 3D planimetry for continuity equation AVA calculation in both tricuspid and bicuspid aortic valves.
Synapse has enriched 10 related papers. Consider them for comparative context: