Answers are grounded in this paper and cite their sources.
Robotic cardiac surgery is a dynamic and adaptable tool capable of safely treating complex pathologies like mitral regurgitation in cardiac dextroversion while minimizing invasiveness.
Central MessageRobotic surgery is a dynamic tool in the cardiac surgery armamentarium that can be adapted to an array of technically challenging patient pathologies and procedures while minimizing invasiveness.See Article page 12. We commend Bourdillon and colleagues1Bourdillon A. Elder R. Lalonde M. Steele J. Gruber P.J. Geirsson A. Robotic mitral valve repair in a patient with cardiac dextroversion.J Thorac Cardiovasc Surg Tech. 2022; 11: 12-16Scopus (3) Google Scholar on this case, which details the successful treatment of mitral regurgitation in a patient with cardiac dextroversion. We believe this report offers valuable insight into not only the recovery advantages of a robotic approach but also its ability to treat complex cardiac surgical pathologies that have traditionally required open intervention. The approach to mitral valve repair has significantly evolved within the past several decades. Initial attempts at modern repair were influenced by Dr Alain Carpentier in 1983,2Carpentier A. Cardiac valve surgery—the “French correction.”.J Thorac Cardiovasc Surg. 1983; 86: 323-337https://doi.org/10.1016/S0022-5223(19)39144-5Abstract Full Text PDF PubMed Google Scholar when he discussed mitral valve disease and the steps needed for safe and effective reconstruction. The approach to exposure at this time and for many subsequent years after was through median sternotomy, which allows for direct visualization and exposure to the entire heart and vessels.3Glauber M. Miceli A. State of the art for approaching the mitral valve: sternotomy, minimally invasive or total endoscopic robotic?.Eur J Cardiothorac Surg. 2015; 48: 639-641https://doi.org/10.1093/EJCTS/EZV312Crossref PubMed Scopus (0) Google Scholar Dr Carpentier and his team reported favorable outcomes through open sternotomy, with strong freedom from cardiac-related morbidity and mortality in addition to low rates of reoperation.4Braunberger E. Deloche A. Berrebi A. Fayssoil A. Celestin J.A. Melmoun P. et al.Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.Circulation. 2001; 104: I8-I11https://doi.org/10.1161/CIRC.104.SUPPL_1.I-8-11Crossref PubMed Google Scholar In recent years, surgeons have turned to less invasive alternatives, including minimally invasive mitral valve surgery (MIMVS) and robotic surgery to avoid open sternotomy while continuing to provide high quality results.3Glauber M. Miceli A. State of the art for approaching the mitral valve: sternotomy, minimally invasive or total endoscopic robotic?.Eur J Cardiothorac Surg. 2015; 48: 639-641https://doi.org/10.1093/EJCTS/EZV312Crossref PubMed Scopus (0) Google Scholar MIMVS typically refers to operating through a right-sided minithoracotomy or ministernotomy.3Glauber M. Miceli A. State of the art for approaching the mitral valve: sternotomy, minimally invasive or total endoscopic robotic?.Eur J Cardiothorac Surg. 2015; 48: 639-641https://doi.org/10.1093/EJCTS/EZV312Crossref PubMed Scopus (0) Google Scholar Robotic assistance is added by some to the minithoracotomy. Totally endoscopic robotic mitral valve surgery is performed with a robotically controlled endoscope and wristed remotely controlled instruments and an 8 to 30 mm working port without any rib spreading, an even less invasive approach than MIMVS. There are data to support shorter hospital stay lengths and noninferior postoperative outcomes in patients undergoing robotic versus normal repair.5Cao C. Wolfenden H. Liou K. Pathan F. Gupta S. Nienaber T.A. et al.A meta-analysis of robotic vs. conventional mitral valve surgery.Ann Cardiothorac Surg. 2015; 4: 305-314https://doi.org/10.3978/J.ISSN.2225-319X.2014.10.05Crossref PubMed Google Scholar With an experienced team, robotic surgery can lead to a successful hospital course after mitral valve surgery without the need to open the chest. Successful mitral valve repair in patients with dextroversion requires a complete understanding of the anatomic variations, such as the positioning of the pulmonary trunk relative to the aorta discussed by the authors.1Bourdillon A. Elder R. Lalonde M. Steele J. Gruber P.J. Geirsson A. Robotic mitral valve repair in a patient with cardiac dextroversion.J Thorac Cardiovasc Surg Tech. 2022; 11: 12-16Scopus (3) Google Scholar Furthermore, patients with dextroversion and situs solitus may also present with additional technical challenges such as univentricular systems and atrioventricular discordance.6Offen S. Jackson D. Canniffe C. Choudhary P. Celermajer D.S. Dextrocardia in adults with congenital heart disease.Heart Lung Circ. 2016; 25: 352-357https://doi.org/10.1016/J.HLC.2015.09.003Abstract Full Text Full Text PDF PubMed Google Scholar Its very interesting to see that the mitral valve is upside down compared with normal anatomy. We would like to specifically highlight the adaptability of robotic port placement demonstrated by this case. At our center, ports for robotic mitral valve repair are typically placed on the patient's right side in approximately the third through seventh intercostal spaces in the right axilla to facilitate access to left atrium. However, the dextrocardia present in the authors' patient required port placement on the patient's left side, reversing the typical robotic approach to access the patient's reversed cardiac anatomy. Although cardiac dextroversion is quite rare, with an estimated incidence of approximately 1 in 12,000 pregnancies,7Bohun C.M. Potts J.E. Casey B.M. Sandor G.G.S. A population-based study of cardiac malformations and outcomes associated with dextrocardia.Am J Cardiol. 2007; 100: 305-309https://doi.org/10.1016/J.AMJCARD.2007.02.095Abstract Full Text Full Text PDF PubMed Scopus (0) Google Scholar this case highlights the broader adaptability of robotic cardiac surgery, which allows the operative approach to be tailored to each patient's unique technical challenges. The ultimate goal for surgical interventions beyond safety and efficacy is to minimize invasiveness and thus maximize patient satisfaction. As evidenced by the authors' successful completion of a complex robotic mitral valve repair in a patient with cardiac dextroversion, robotic cardiac surgery is a dynamic tool capable of achieving this goal. With adequate investment in the requisite equipment and personnel training, we believe the robotic approach offers a safe and effective means to usher in an era of minimally invasive cardiac surgery for the treatment of complicated pathologies that have traditionally required open surgery. Robotic mitral valve repair in a patient with cardiac dextroversionJTCVS TechniquesVol. 11PreviewA 25-year-old woman with dextroversion was found to have moderate mitral regurgitation (MR) complicated by systolic anterior motion (SAM) of the anterior leaflet, causing obstruction of the aortic valve and left ventricular outflow tract (LVOT). The patient presented with increasing symptoms of intermittent nonexertional chest pressure and dyspnea on exertion. A preoperative transthoracic echocardiogram revealed worsening MR and LVOT obstruction with a peak resting gradient of 37 mm Hg and 70 mm Hg on provocative testing.
No takes yet. Share an insight, caveat, or question.
Yost et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: