Why the study?
Availability of hs-cTn measurements at point-of-care can improve timely management of AMI patients, prompting a roadmap for regulatory and analytical validation.
The Atellica VTLi hs-cTnI point-of-care system demonstrated high-sensitivity analytical performance and excellent agreement between plasma and whole blood, supporting its potential use for rapid AMI diagnosis.
Answers are grounded in this paper and cite their sources.
Supports point-of-care hs-cTnI testing for rapid AMI diagnosis; confirms high-sensitivity performance across matrices.
BACKGROUND: High-sensitivity cardiac troponin (hs-cTn) assays enable more precise use of traditional diagnostic strategies and earlier rule-out/rule-in at 0/1 h or 0/2 h after presentation of acute myocardial infarction (AMI). Availability of hs-cTn measurements at point-of-care (POC) can improve timely management of AMI patients. A roadmap for regulatory and analytical validation is exemplified with studies with the Atellica VTLi hs-cTnI at POC. METHODS: High-sensitivity performance was assessed with AACC/IFCC expert recommendations. Clinical Laboratory Standards Institute protocols were used for characterizing limit of blank, limit of detection (LoD), limit of quantitation (LoQ), 10% CV, precision, linearity, and analytic specificity with several reagent lots. Bland-Altman, Passing-Bablok, and hematocrit bias plots compared hs-cTnI measurement in lithium-heparin plasma (PL) and whole blood (WB) matrices. RESULTS: LoB was 0.55 ng/L; LoD and LoQ were 1.24 ng/L and 2.1 ng/Lm for PL and 1.60 ng/L and 3.7 ng/L for WB, respectively. The male 99th percentile is 27 ng/L, and female 99th percentile upper reference limit is 18 ng/L; 10% CVs were 6.7 ng/L for PL and 8.9 ng/L for WB. Also ≥50% of hs-cTnI values for healthy cohorts exceeded the LoD, confirming high-sensitivity performance. Linearity spanned from LoQ to 1250 ng/L. Specificity was >90% for 40 potential interferences; no hook effect was detected. WB and PL correlation was WB = 1.02*plasma + 0.3 ng/L (r = 0.996, n = 152). No hs-cTnI association with hematocrit was detected (R2 = 0.003). CONCLUSION: This analytical roadmap showed high-sensitivity performance, good analytic characteristics, and excellent PL and WB agreement for the Atellica VTLi hs-cTnI POC system. Essential clinical performance studies in patients by intended POC users may now commence.
No takes yet. Share an insight, caveat, or question.
Christenson et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: