Accelerometry is an emerging tool for real-time functional capacity evaluation in PAH, but its relationship with right ventricular echocardiographic measurements has not been established.
Do right ventricular echocardiography measurements correlate with functional capacity assessed by accelerometry in patients with pulmonary arterial hypertension?
Do right ventricular echocardiography measurements correlate with functional capacity assessed by accelerometry in patients with pulmonary arterial hypertension?
Tricuspid regurgitant peak velocity and pulmonary artery acceleration time on echocardiography correlate significantly with functional capacity measured by accelerometry in patients with PAH.
BACKGROUND: Accelerometry is an emerging option for real-time evaluation of functional capacity in patients with pulmonary arterial hypertension (PAH). This prospective pilot study assesses the relationship between functional capacity by accelerometry and right ventricular measurements on echocardiography for this high-risk cohort. METHODS: Patients with PAH were prospectively enrolled and underwent 6-Minute Walk Test and cardiopulmonary exercise testing. They were given a Fitbit, which collected steps and sedentary time per day. Echocardiographic data included right ventricular global longitudinal, free wall, and septal strain; tricuspid regurgitant peak velocity; tricuspid annular plane systolic excursion; tricuspid annular plane systolic velocity; right ventricular myocardial performance index; and pulmonary artery acceleration time. Pairwise correlations were performed. RESULTS: The final analysis included 22 patients aged 13 to 59 years. Tricuspid regurgitant peak velocity had a negative correlation with 6-Minute Walk Test (r = -0.58, P = .02), peak oxygen consumption on exercise testing (r = -0.56, P = .03), and average daily steps on accelerometry (r = -0.59, P = .03), but a positive correlation with median sedentary time on accelerometry (r = 0.64, P = .02). Pulmonary artery acceleration time positively correlated with peak oxygen consumption on exercise testing (r = 0.64, P = .002). There was no correlation between right ventricular strain measurements and functional capacity testing. CONCLUSION: In this pilot study, tricuspid regurgitant jet and pulmonary artery acceleration time were the echocardiographic variables that correlated most with accelerometry data. With further echocardiographic validation, accelerometry can be a useful, noninvasive, and cost-effective tool to monitor disease progression in patients with PAH.
No takes yet. Share an insight, caveat, or question.
Woo et al. (2022) studied this question.