Why the study?
Confluent inferior pulmonary veins is a rare anatomical variant with little evidence regarding anatomic landmarks to guide radiofrequency application and avoid esophageal complications.
Does the 'tri-circle' ablation technique safely isolate pulmonary veins while avoiding the extremely thin posterior wall in patients with confluent inferior pulmonary veins?
Does the 'tri-circle' ablation technique safely isolate pulmonary veins while avoiding the extremely thin posterior wall in patients with confluent inferior pulmonary veins?
The posterior wall of confluent inferior pulmonary veins is extremely thin, necessitating modified ablation strategies like the 'tri-circle' technique to safely achieve isolation without esophageal injury.
Answers are grounded in this paper and cite their sources.
Thin CIPV posterior walls may raise esophageal injury risk during ablation; leaves open optimal isolation strategies for this rare anatomy.
BACKGROUND: Confluent inferior pulmonary veins (CIPV) is a rare anatomical variant. There is few evidence in the literature regarding anatomic landmarks consideration to guide radiofrequency application in avoiding complications in the esophagus in CIPV cases. METHODS: Of 986 consecutive patients undergoing atrial fibrillation (AF) ablation from July 2020 to June 2022, seven (0.7%) had CIPV with a common trunk connecting to the LA diagnosed by 3-dimensional contrast-enhanced computed tomography. Using intracardiac echocardiography (ICE) performed from the left atrium (LA), we measured the posterior wall thickness (PWT) of the CIPV adjacent to the esophagus and compared the measurement with the LA posterior wall thickness (LAPWT) at the left inferior PV level of 25 controls without CIPV. For ablation in CIPV patients, each superior PV was individually isolated, and box isolation of CIPV without ablating the CIPV posterior wall was added (tri-circle ablation technique). RESULTS: The CIPV PWT was 0.7 ± 0.1 mm, while non-CIPV LAPWT was 2.0 ± 0.4 mm (P < 0.001). In the CIPV group, upper and lower portions of the CIPV were both apart from the esophagus (mean distances, 6.7 ± 3.4 mm and 7.9 ± 2.7 mm, respectively). Individual superior PV isolation and box CIPV isolation resulted in complete isolation of all PVs, with no complications. All CIPV patients except one remained AF recurrence-free for 376 ± 52 days. CONCLUSIONS: Although CIPV frequency is low, CIPV PWT is very thin and special care is needed during ablation. A "tri-circle" ablation strategy avoids ablating in the thinnest portion of the posterior wall. Further studies are warranted to assess the safety.
No takes yet. Share an insight, caveat, or question.
Negishi et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: