Answers are grounded in this paper and cite their sources.
Assessing the condition of wall ties in masonry cavity wall systems using a non-destructive approach is challenging due to the hidden nature of installation and subtle wall tie deterioration mechanisms. This study presents a vibration-based damage identification approach to address this issue using the impact hammer test. The test measured the natural frequencies and the corresponding mode shapes of a one-story masonry cavity wall with six different test cases of wall tie deterioration. A significant reduction in natural frequencies of up to 64% was observed when all wall ties were fully cut, indicating the suitability of using natural frequency as a damage detection indicator. In terms of damage localisation, four mode shape-based analyses were compared and discussed, including the coordinate modal assurance criterion (COMAC), parameter-based method, curvature damage factor (CDF) and mode shape derivative-based damage identification method (MSDBDI). Among the four mode shape-based methods, parameter-based and CDF methods demonstrated a higher accuracy in locating damage locations by identifying high damage indices near the affected regions. The findings highlight the potential of vibration-based damage identification methods for the detection of wall tie deterioration and contribute to a more robust structural risk assessment for masonry structures.
No takes yet. Share an insight, caveat, or question.
Lam et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: