The Editor, Laryngoscope malfunction is one of the frequent equipment failures encountered during endotracheal intubation by anaesthesiologists.[1] Failure of the laryngoscope during intubation is a serious event that can result in life-threatening consequences such as oxygen desaturation, dysrhythmia and cardiac arrest. Common laryngoscope malfunction includes failing light source, defective bulb, faulty contact between the blade and the handle or in the socket and dead/low battery. A thorough check of the laryngoscope parts before its use will detect most of the malfunctions and these should be corrected before its use. Omitting this precautionary step may result in airway disaster, particularly during a rapid-sequence endotracheal intubation. In this report, we address an uncommon occurrence of laryngoscope malfunction, specifically the fracture of the laryngoscope blade at its base during the laryngoscopy procedure on an adult male patient. This had occurred despite a preinduction check of the instrument. In this case, we used Macintosh laryngoscope of blade size 4 (manufactured by Laproworld Instrument Co., Rajkot, Gujrat, India). Written and informed consent for publication was taken from the patient. The laryngoscope blade broke completely from its base, despite the laryngoscopy being conducted with the usual effort [Figure 1]. A different laryngoscope, which was accessible, was used to achieve successful intubation of the patient. Possible causes behind laryngoscope breakage include (1) use of different material for manufacture, (2) repeated cleaning and sterilisation contributing to accelerated corrosion and (3) metal fatigue from chronic use, use of excessive force during laryngoscopy/faulty technique by the anaesthesiologist.Figure 1: Laryngoscope with broken blade at baseBefore being used on patients, the metallic laryngoscopes undergo testing to assess their vertical deflection and ultimate strength. The stress test of the blade handle’s vertical deflection may be conducted using the Instron materials testing machines. The resulting force (measured in Newtons) and displacement data (measured in millimetres) are recorded. The force on each blade is increased until it reaches either its structural limit or a predetermined maximum load of 200 N. The ISO standard specifies that the vertical displacement of the blade tip under a load of 65 N is obtained from the force deflection curves.[2] The ultimate failure load may also be measured in relation to the ISO load criterion for structural integrity, which is 150 N. A frequent mechanism of failure found in the blades is the occurrence of cracking or significant distortion at the hinge attachment slot. Few incidences of laryngoscope breakages were also reported earlier.[3-5] To prevent such incident in future, we suggest that blade and handle stress test should be included in the preanaesthetic check of the laryngoscope apart from electrical integrity test of the laryngoscope. A reserve laryngoscope, equipped with an appropriately sized blade, must be available before the initiation of anaesthesia. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: