Digital isolators are widely used in isolated power converters for transmitting high-frequency gating pulses. Conventional opto-isolators suffer from low reliability and poor delay matching, while emerging RF based isolators are either expensive or power-hungry. In this work, a Phase-Locked-Loop (PLL) based synchronization scheme is demonstrated to operate a bi-directional Dual-Active-Bridge (DAB) dc-dc converter without any digital isolators. The converter is targeted to renewable energy applications with integrated storage. The reference clock is generated on the secondary-side controller and sensed on the primary-side using the main power transformer. A synchronized clock within the primary-side controller is generated using the PLL by modulating the supply voltage of a voltage controlled oscillator. The proposed method is implemented and demonstrated on a 150 W, 94.2% efficient DAB converter prototype. With this synchronization scheme in place, low-frequency communication across the isolation transformer is also demonstrated by modulating the switching frequency.
No takes yet. Share an insight, caveat, or question.
Poshtkouhi et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: